02108 THE USE OF INNOVATIVE INSTALLATION METHODS FOR PROTECTION OF LARGE GROUPS OF ABOVEGROUND FUEL STORAGE TANKS

Product Number: 51300-02108-SG
ISBN: 02108 2002 CP
Author: Paul S. Rothman, Frank G. Hemerlein, and Nicholas Pressly
$0.00
$20.00
$20.00
The application of cathodic protection (CP) to steel bottoms of large groups of aboveground fuel storage tanks and monitoring the effectiveness of the systems poses several unique complications. The objectives of these systems are to provide uniform current distribution to all areas of the tank bottom, while causing minimal disruption of facility operations and limiting the amount of influence on other piping systems in the area. The requirement to apply CP to the bottoms of 40 aboveground tanks at the Satellite Tank Farm at John F. Kennedy International Airport presented unique obstacles. These included the congested nature of the facility, the existence of multiple fuel systems entering the Tank Farm whose CP systems require electrical isolation from the tanks, the numerous underground crossings of these lines. The monitoring of the protection levels at the critical locations on the tank bottoms, as well as at the critical interfaces between piping systems, presented additional challenges. The consideration of the above requirements led to a system design and installation methods that proved innovative in nature and enhanced available technology for the future application of CP to such structures. The installation methods included horizontal directional drilling and insertion of anode casings, as well as air jetting of reference electrodes under the tanks. The systems will also include state-of-the-art remote monitoring capabilities.
The application of cathodic protection (CP) to steel bottoms of large groups of aboveground fuel storage tanks and monitoring the effectiveness of the systems poses several unique complications. The objectives of these systems are to provide uniform current distribution to all areas of the tank bottom, while causing minimal disruption of facility operations and limiting the amount of influence on other piping systems in the area. The requirement to apply CP to the bottoms of 40 aboveground tanks at the Satellite Tank Farm at John F. Kennedy International Airport presented unique obstacles. These included the congested nature of the facility, the existence of multiple fuel systems entering the Tank Farm whose CP systems require electrical isolation from the tanks, the numerous underground crossings of these lines. The monitoring of the protection levels at the critical locations on the tank bottoms, as well as at the critical interfaces between piping systems, presented additional challenges. The consideration of the above requirements led to a system design and installation methods that proved innovative in nature and enhanced available technology for the future application of CP to such structures. The installation methods included horizontal directional drilling and insertion of anode casings, as well as air jetting of reference electrodes under the tanks. The systems will also include state-of-the-art remote monitoring capabilities.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for Upgrading Methods of Cathodic Protection System for Aboveground Storage Tanks
Available for download

51316-7462-Upgrading Methods of Cathodic Protection System for Aboveground Storage Tanks

Product Number: 51316-7462-SG
ISBN: 7462 2016 CP
Author: Mohammed Al-Otaibi
Publication Date: 2016
$20.00
Picture for 02109 Improved Cathodic Protection Testing...
Available for download

02109 Improved Cathodic Protection Testing Techniques For Aboveground Storage Tank Bottoms

Product Number: 51300-02109-SG
ISBN: 02109 2002 CP
Author: Louis Koszewski
$20.00
Picture for 00829 TECHNIQUES FOR ACCURATE EVALUATION OF
Available for download

00829 TECHNIQUES FOR ACCURATE EVALUATION OF ABOVEGROUND STORAGE TANK CATHODIC PROTECTION SYSTEM EFFECTIVENESS

Product Number: 51300-00829-SG
ISBN: 00829 2000 CP
Author: Tim Whited
$20.00