Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51312-01155-General consideration about current distribution and potential attenuation based on storage tank bot

Product Number: 51312-01155-SG
ISBN: 01155 2012 CP
Author: Bob Adey
Publication Date: 2012
$0.00
$20.00
$20.00
In cathodic protection the efficiency of cathodic protection is driven by various environmental parameters. The main ones are: the geometry of the protected structure the electrolyte resistivity and of course the steel polarization curve. The aim of this study is to assess notably the influence of those parameters on the current distribution and on the potential attenuation. In particular an attempt to solve the apparently controversial influence of the resistivity will be proposed. In order to achieve these results the cases of storage tanks bottom are studied by 3D modeling for two configurations. The first one concern the tank bottom for which a membrane is installed few tens of cm underneath with the anodic grid system located in the confined space. The second one is the usual design where no membrane is installed below the tank and where some anodes are located at the periphery of the tank
In cathodic protection the efficiency of cathodic protection is driven by various environmental parameters. The main ones are: the geometry of the protected structure the electrolyte resistivity and of course the steel polarization curve. The aim of this study is to assess notably the influence of those parameters on the current distribution and on the potential attenuation. In particular an attempt to solve the apparently controversial influence of the resistivity will be proposed. In order to achieve these results the cases of storage tanks bottom are studied by 3D modeling for two configurations. The first one concern the tank bottom for which a membrane is installed few tens of cm underneath with the anodic grid system located in the confined space. The second one is the usual design where no membrane is installed below the tank and where some anodes are located at the periphery of the tank
Product tags
Also Purchased
Picture for 08059 Current and Potential Distribution Modeling for CP of Tank Bottoms
Available for download

08059 Current and Potential Distribution Modeling for CP of Tank Bottoms

Product Number: 51300-08059-SG
ISBN: 08059 2008 CP
Author: Bruno Bazzoni, Sergio Lorenzi, Paolo Marcassoli, and Tommaso Pastore
Publication Date: 2008
$20.00
Picture for 00829 TECHNIQUES FOR ACCURATE EVALUATION OF
Available for download

00829 TECHNIQUES FOR ACCURATE EVALUATION OF ABOVEGROUND STORAGE TANK CATHODIC PROTECTION SYSTEM EFFECTIVENESS

Product Number: 51300-00829-SG
ISBN: 00829 2000 CP
Author: Tim Whited
$20.00
Picture for 04091Cathodic Protection Design of Pipelines
Available for download

04091 Cathodic Protection Design of Pipelines Using an Improved Attenuation Model

Product Number: 51300-04091-SG
ISBN: 04091 2004 CP
Author: John P. LaFontaine, Champlain Group Inc.; Grant T. Gibson, GATE LLC
$20.00