Above ground tanks for storage of liquid hydrocarbon are often erected with secondary containment membrane installed below the tank bottom to prevent the soil contamination in case of leakage. The design of impressed current cathodic protection in presence of the plastic membrane is based on distributed anodes installed in the space between the tank bottom and the membrane; among available anodes, the most commonly used are the titanium grid or ribbon activated with noble metal oxides. The configuration of the grid or ribbon anode system confined in the closed space between bottom and membrane creates specific issues concerning the electrochemical reactions occurring at anode and cathode, the ohmic drops in the anode system and the potential and current distribution at the cathode. The paper shows results of a number of numeric simulations performed to predict the actual distribution of current and potential. Design criteria are discussed.
Above ground tanks for storage of liquid hydrocarbon are often erected with secondary containment membrane installed below the tank bottom to prevent the soil contamination in case of leakage. The design of impressed current cathodic protection in presence of the plastic membrane is based on distributed anodes installed in the space between the tank bottom and the membrane; among available anodes, the most commonly used are the titanium grid or ribbon activated with noble metal oxides. The configuration of the grid or ribbon anode system confined in the closed space between bottom and membrane creates specific issues concerning the electrochemical reactions occurring at anode and cathode, the ohmic drops in the anode system and the potential and current distribution at the cathode. The paper shows results of a number of numeric simulations performed to predict the actual distribution of current and potential. Design criteria are discussed.
Product tags
Also Purchased
Picture for General consideration about current distribution and potential attenuation based on storage tank bot
Available for download

51312-01155-General consideration about current distribution and potential attenuation based on storage tank bot

Product Number: 51312-01155-SG
ISBN: 01155 2012 CP
Author: Bob Adey
Publication Date: 2012
$20.00
Picture for Corrosion Protection of Storage Tank Soil Side Bottoms—Application Experience
Available for download

51315-6016-Corrosion Protection of Storage Tank Soil Side Bottoms—Application Experience

Product Number: 51315-6016-SG
ISBN: 6016 2015 CP
Author: Efim Lyublinski
Publication Date: 2015
$0.00
Picture for 08058 Prevention of External (Soil Side) Corrosion on Storage Tank Bottom Plates by Cathodic Protect
Available for download

08058 Prevention of External (Soil Side) Corrosion on Storage Tank Bottom Plates by Cathodic Protection System

Product Number: 51300-08058-SG
ISBN: 08058 2008 CP
Author: Bipradas Chatterjee
Publication Date: 2008
$20.00