Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51318-11073-Development of a Reference Electrode for Study of Supercritical CO2 Corrosion

Two methods to prepare tungsten/tungsten oxide as reference electrode for performing electrochemical measurements in H2O-saturated super critical (SC) CO2 phase

Product Number: 51318-11073-SG
Author: Chin-Hua Cheng / Jing Ning / Raymundo Case
Publication Date: 2018
$0.00
$20.00
$20.00

 Two methods to prepare tungsten/tungsten oxide as reference electrode for performing electrochemical measurements in H2O-saturated super critical (SC) CO2 phase in the study. The W/Woxide reference electrodes are fabricated using electrochemical or thermal oxidation.

The stability of each type of tungsten/tungsten oxide electrodes is verified by comparing the potential in brine solutions containing MEG up to 100ºC with exposure time over 48 hours. The results are consistent with literature that the reference potential decreases with the increase in temperature. The results also show that the thermal-prepared W/Woxide reference electrode is stable at high temperature.

The W/Woxide reference electrode is employed to electrochemically test carbon steel (Q-125) in the SC-CO2 at 65ºC. It is found that the W/Woxide reference electrode can be used for studying the electrochemical mechanism of carbon steel corrosion in SC-CO2, assessing the effect of changing oxidizing conditions of the SC-CO2 environment on the carbon steel corrosion kinetics.

Keywords: Corrosion, tungsten, supercritical, electrochemistry

 

 Two methods to prepare tungsten/tungsten oxide as reference electrode for performing electrochemical measurements in H2O-saturated super critical (SC) CO2 phase in the study. The W/Woxide reference electrodes are fabricated using electrochemical or thermal oxidation.

The stability of each type of tungsten/tungsten oxide electrodes is verified by comparing the potential in brine solutions containing MEG up to 100ºC with exposure time over 48 hours. The results are consistent with literature that the reference potential decreases with the increase in temperature. The results also show that the thermal-prepared W/Woxide reference electrode is stable at high temperature.

The W/Woxide reference electrode is employed to electrochemically test carbon steel (Q-125) in the SC-CO2 at 65ºC. It is found that the W/Woxide reference electrode can be used for studying the electrochemical mechanism of carbon steel corrosion in SC-CO2, assessing the effect of changing oxidizing conditions of the SC-CO2 environment on the carbon steel corrosion kinetics.

Keywords: Corrosion, tungsten, supercritical, electrochemistry

 