This paper discusses the design philosophy for corrosion inhibitors used for carbon capture, transportation, and storage and the performance testing using rotating cylinder autoclave (RCA) and electrochemical impedance spectroscopy (EIS) methods under CO2 supercritical conditions.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Carbon Capture and Storage (CCS). The CO2 stream, captured from power plants contains highly corrosive impurities including H2O vapor, oxygen, and hydrogen sulfide. This paper presents our study on corrosion of pipeline steel in sc-CO2 containing H2O, H2S and/or O2 impurities in an autoclave.
The Supercritical Carbon Dioxide Corrosion Test Facility is equipped with 3 high-temperature, high-pressure vessels and a gas-phase Fourier transform infrared spectrometer (FTIR) for simultaneous in situ monitoring of key contaminants. This paper outlines the capabilities of this new National Institute of Standards and Technology facility.