Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

A Study of the Compatibility of Carbon Steel for MEG Reclaiming Systems: Impact of pH Adjustment

Mono-ethylene glycol (MEG) is often injected in offshore gas transport lines to prevent the formation of gas hydrates (crystalline solids comprised of water and gas that form at low temperatures). Glycol is one of the most effective products for this purpose and acts to further lower the temperature at which hydrates would normally form. As such, it is called a thermodynamic inhibitor.

Product Number: 51323-19467-SG
Author: J. Kittel, F. Grosjean, G.R. Joshi, G. Parer, F. Quinio, JC Brevot
Publication Date: 2023
$0.00
$20.00
$20.00

In this communication, we will describe an integrated monoethylene (MEG)-reclaiming process using carbon steels metallurgy for most of the lines and vessels that handle MEG slurry solutions. Due to the potentially highly corrosive conditions in this type of facility, corrosion resistant alloys such as duplex stainless steels often constitute the preferred option for this process. The aim of this work is to check if carbon steels represent a viable alternative. Corrosion tests were conducted on carbon steel (UNS K02100) and a duplex stainless steel (UNS S32205) at 120°C in MEG solutions saturated with salts and containing suspended solids. The main parameters that were investigated are oxygen contamination, pH level from acid (close to pH 4) to alkaline (pH above 10), and the type of chemical used for pH control (NaOH and Na2CO3). The results show that carbon steel could be used in reclaiming application operating under certain conditions, provided that pH control is properly applied.

In this communication, we will describe an integrated monoethylene (MEG)-reclaiming process using carbon steels metallurgy for most of the lines and vessels that handle MEG slurry solutions. Due to the potentially highly corrosive conditions in this type of facility, corrosion resistant alloys such as duplex stainless steels often constitute the preferred option for this process. The aim of this work is to check if carbon steels represent a viable alternative. Corrosion tests were conducted on carbon steel (UNS K02100) and a duplex stainless steel (UNS S32205) at 120°C in MEG solutions saturated with salts and containing suspended solids. The main parameters that were investigated are oxygen contamination, pH level from acid (close to pH 4) to alkaline (pH above 10), and the type of chemical used for pH control (NaOH and Na2CO3). The results show that carbon steel could be used in reclaiming application operating under certain conditions, provided that pH control is properly applied.

Also Purchased
Picture for Qualification of scale and corrosion inhibitor for a subsea HPHT field with a MEG-loop
Available for download

51312-01517-Qualification of scale and corrosion inhibitor for a subsea HPHT field with a MEG-loop

Product Number: 51312-01517-SG
ISBN: 01517 2012 CP
Author: Jan Ivar Skar
Publication Date: 2012
$20.00
Picture for 07116 Materials Considerations for MEG Reclaim Systems
Available for download

07116 Materials Considerations for MEG Reclaim Systems

Product Number: 51300-07116-SG
ISBN: 07116 2007 CP
Author: Michael W. Joosten, Marion Siersten, Ben Tier, and Christian Wintermark
Publication Date: 2007
$20.00
Picture for 07024 QUALIFICATION OF INTERNAL COATINGS FOR MEG/WATER STORAGE TANKS AT THE ORMEN LANGE ONSHORE PROC
Available for download

07024 QUALIFICATION OF INTERNAL COATINGS FOR MEG/WATER STORAGE TANKS AT THE ORMEN LANGE ONSHORE PROCESSING PLANT

Product Number: 51300-07024-SG
ISBN: 07024 2007 CP
Author: J.I. Skar, T.R. Andersen and A.M.K. Halvorsen
Publication Date: 2007
$20.00