Pipelines have the highest capacity and are the safest and least environmentally disruptive way for gas or oil transmission. Recently, failures due to corrosion defects became of major concern in maintaining pipeline integrity. A number of solutions have been developed for the assessment of remaining strength of corroded pipelines. However, these solutions are known to be dependent on material properties and pipeline geometries. In this paper, a Fitness-For-Purpose(FFP) type limit load solutions for corroded gas pipelines made of X65 steel is proposed based on experimental results and finite element analyses. For this purpose, a series of burst test with various types of corrosion defects were performed. Finite element simulation was carried out on burst test to derive failure criteria. And then, an extensive series of finite element analyses were performed to obtain a limit load solution for single corrosion defect on the basis of burst test simulation. As a result, an FFP type limit load solution for corroded X65 gas pipelines was proposed.
Pipelines have the highest capacity and are the safest and least environmentally disruptive way for gas or oil transmission. Recently, failures due to corrosion defects became of major concern in maintaining pipeline integrity. A number of solutions have been developed for the assessment of remaining strength of corroded pipelines. However, these solutions are known to be dependent on material properties and pipeline geometries. In this paper, a Fitness-For-Purpose(FFP) type limit load solutions for corroded gas pipelines made of X65 steel is proposed based on experimental results and finite element analyses. For this purpose, a series of burst test with various types of corrosion defects were performed. Finite element simulation was carried out on burst test to derive failure criteria. And then, an extensive series of finite element analyses were performed to obtain a limit load solution for single corrosion defect on the basis of burst test simulation. As a result, an FFP type limit load solution for corroded X65 gas pipelines was proposed.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 02087 INTERNAL CORROSION DIRECT ASSESSMENT...
Available for download

02087 INTERNAL CORROSION DIRECT ASSESSMENT OF GAS TRANSMISSION PIPELINES

Product Number: 51300-02087-SG
ISBN: 02087 2002 CP
Author: Oliver Moghissi, Lee Norris, Phil Dusek, and Bruce Cookingham
$20.00
Picture for 00829 TECHNIQUES FOR ACCURATE EVALUATION OF
Available for download

00829 TECHNIQUES FOR ACCURATE EVALUATION OF ABOVEGROUND STORAGE TANK CATHODIC PROTECTION SYSTEM EFFECTIVENESS

Product Number: 51300-00829-SG
ISBN: 00829 2000 CP
Author: Tim Whited
$20.00