Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51314-4043-Using Distributions to Characterize Corrosion Damage

Product Number: 51314-4043-SG
ISBN: 4043 2014 CP
Author: Peter Wilson
Publication Date: 2014
$0.00
$20.00
$20.00
Non destructive Testing (NDT) is commonly used to assess the condition of corroding plant including piping and pipelines. In particular measuring instruments using ultrasound are used to find locations where loss of wall thickness has occurred and to determine the extent of the loss. Inherent in the measurement of wall thickness is the assumption that from a limited set of measurements it is possible to infer the condition of a vessel or section of piping. The determination of corrosion rate then requires a reassessment of the wall thickness at a later date. For old plant the variability in corrosion damage both in a spatial sense and in depth of loss causes a difficulty in finding the worst case losses in wall thickness and in determining remaining life. It is also necessary to recognize that the measurement error depends on the skill applied by the inspector during the inspection. This paper discusses the use of probability of detection concepts for finding corrosion damage and illustrates it for a corroding vessel inspected over a 2 year period. It also describes the use of distributions of wall loss to characterize the condition of corroding pipelines. The incorporation of statistical principles into data analysis is required because of the inherent variability of corrosion damage.
Non destructive Testing (NDT) is commonly used to assess the condition of corroding plant including piping and pipelines. In particular measuring instruments using ultrasound are used to find locations where loss of wall thickness has occurred and to determine the extent of the loss. Inherent in the measurement of wall thickness is the assumption that from a limited set of measurements it is possible to infer the condition of a vessel or section of piping. The determination of corrosion rate then requires a reassessment of the wall thickness at a later date. For old plant the variability in corrosion damage both in a spatial sense and in depth of loss causes a difficulty in finding the worst case losses in wall thickness and in determining remaining life. It is also necessary to recognize that the measurement error depends on the skill applied by the inspector during the inspection. This paper discusses the use of probability of detection concepts for finding corrosion damage and illustrates it for a corroding vessel inspected over a 2 year period. It also describes the use of distributions of wall loss to characterize the condition of corroding pipelines. The incorporation of statistical principles into data analysis is required because of the inherent variability of corrosion damage.
Product tags
Also Purchased
Picture for CORROSION OF CARBON STEEL IN CO2 CAPTURE PLANT USING MDEA AND AMINO ACID BASED SOLVENTS
Available for download

51312-01554-CORROSION OF CARBON STEEL IN CO2 CAPTURE PLANT USING MDEA AND AMINO ACID BASED SOLVENTS

Product Number: 51312-01554-SG
ISBN: 01554 2012 CP
Author: Peter T. Wilson
Publication Date: 2012
$20.00
Picture for Corrosion Control System Performance for Large Diameter Water Mains in a Light -Rail and Interstate
Available for download

51314-4008-Corrosion Control System Performance for Large Diameter Water Mains in a Light -Rail and Interstate

Product Number: 51314-4008-SG
ISBN: 4008 2014 CP
Author: Stuart Greenberger
Publication Date: 2014
$20.00
Picture for ICCP System Design on the Hull of an Ice Breaker by Computational Analysis
Available for download

51314-4004-ICCP System Design on the Hull of an Ice Breaker by Computational Analysis

Product Number: 51314-4004-SG
ISBN: 4004 2014 CP
Author: Min Jung Lee
Publication Date: 2014
$20.00