Search
Filters
Close

51315-5917-The Effects of Balance Gas on Sour Corrosion and HIC Behavior of Carbon Steel

Product Number: 51315-5917-SG
ISBN: 5917 2015 CP
Author: Kenji Kobayashi
Publication Date: 2015
$0.00
$20.00
$20.00
Hydrogen Induced Cracking (HIC) is a major issue of line pipe steels exposed to sour environments. In general 5.0 wt% NaCl and 0.5 wt% CH3COOH solution with 0.1 MPa H2S provided by NACE TM0284 as solution A is used to evaluate the HIC resistance of steel products. However in many cases the test condition is too severe compared to the actual field conditions. Therefore appropriate HIC evaluation method under sour conditions has been the subject of considerable investigations in recent years.High-strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) has proposed a HIC test solution with high buffering capacity for simulating and keeping aimed sour condition. The solution has high concentration of acetic acid and sodium acetate. In this study in addition effects of balance gas (N2 and CO2) on pH stability sour corrosion behavior and HIC susceptibility of carbon steel were investigated. From the results an appropriate test solution including balance gas is discussed from the viewpoints of convenience and effectiveness for evaluating the resistance of steels to HIC in sour conditions.
Hydrogen Induced Cracking (HIC) is a major issue of line pipe steels exposed to sour environments. In general 5.0 wt% NaCl and 0.5 wt% CH3COOH solution with 0.1 MPa H2S provided by NACE TM0284 as solution A is used to evaluate the HIC resistance of steel products. However in many cases the test condition is too severe compared to the actual field conditions. Therefore appropriate HIC evaluation method under sour conditions has been the subject of considerable investigations in recent years.High-strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) has proposed a HIC test solution with high buffering capacity for simulating and keeping aimed sour condition. The solution has high concentration of acetic acid and sodium acetate. In this study in addition effects of balance gas (N2 and CO2) on pH stability sour corrosion behavior and HIC susceptibility of carbon steel were investigated. From the results an appropriate test solution including balance gas is discussed from the viewpoints of convenience and effectiveness for evaluating the resistance of steels to HIC in sour conditions.
Also Purchased
Picture for 99425 ALTERNATIVES TO HIC RESISTANT STEELS IN
Available for download

99425 ALTERNATIVES TO HIC RESISTANT STEELS IN SOUR REFINERY ENVIRONMENTS

Product Number: 51300-99425-SG
ISBN: 99425 1999 CP
Author: Brian L. Jack
$20.00
Picture for Hydrogen Cracking of Legacy Steels
Available for download

51315-6199-Hydrogen Cracking of Legacy Steels

Product Number: 51315-6199-SG
ISBN: 6199 2015 CP
Author: Frank Dean
Publication Date: 2015
$20.00
Picture for 08110 Hydrogen Induced Cracking (HIC) - Laboratory Testing Assessment of Low Alloy Steel Linepipe
Available for download

08110 Hydrogen Induced Cracking (HIC) - Laboratory Testing Assessment of Low Alloy Steel Linepipe

Product Number: 51300-08110-SG
ISBN: 08110 2008 CP
Author: John W. Martin, Jean Kittel, Thierry Cassagne, and Christoph Bosch
Publication Date: 2008
$20.00