Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

Optimization of Side-Groove Configuration On DCB Test

The Double Cantilever Beam test method in ANSI NACE TM0177 is increasingly applied as a QA test. In this analysis, influence of various side-groove root configurations (considered to change the stress concentration) on KISSC and Finite Element Analysis results were focused upon.

Product Number: 51317--9102-SG
ISBN: 9102 2017 CP
Author: Jun Nakamura
Publication Date: 2017
$0.00
$20.00
$20.00

The Double Cantilever Beam (DCB) test method standardized in ANSI NACE TM0177 is increasingly applied as a quality assurance test to specify the performance of carbon and low alloy steels for sour service. The DCB test can contribute to the quantitative evaluation of fracture toughness in a specific environment via assessment of the crack arrest of a pre-cracked specimen. The test method has been modified and specified tightly from the view point of specimen geometry test environment and initial stress intensity factor controlled by arm displacement to obtain highly repeatable test results. In this paper the influence of various side-groove root configurations on K1SSC and Finite Element Analysis (FEA) results were focused upon because different types of V notched side-groove roots are considered to change the stress concentration at the bottom of the side-groove and therefore affect the incidence of edge crack occurrence in the DCB test. On the other hand K1SSC value is not changed because K value of different types of V notched side-groove configuration at the middle of thickness is same as a standard DCB test specimen. Decreasing the incidence of edge cracking with increasing V notched side-groove root is discussed from the viewpoint of fracture mechanics.

Key words: Double Cantilever Beam, Edge fracture, Sulfide stress cracking, FEA, K1SSC.

The Double Cantilever Beam (DCB) test method standardized in ANSI NACE TM0177 is increasingly applied as a quality assurance test to specify the performance of carbon and low alloy steels for sour service. The DCB test can contribute to the quantitative evaluation of fracture toughness in a specific environment via assessment of the crack arrest of a pre-cracked specimen. The test method has been modified and specified tightly from the view point of specimen geometry test environment and initial stress intensity factor controlled by arm displacement to obtain highly repeatable test results. In this paper the influence of various side-groove root configurations on K1SSC and Finite Element Analysis (FEA) results were focused upon because different types of V notched side-groove roots are considered to change the stress concentration at the bottom of the side-groove and therefore affect the incidence of edge crack occurrence in the DCB test. On the other hand K1SSC value is not changed because K value of different types of V notched side-groove configuration at the middle of thickness is same as a standard DCB test specimen. Decreasing the incidence of edge cracking with increasing V notched side-groove root is discussed from the viewpoint of fracture mechanics.

Key words: Double Cantilever Beam, Edge fracture, Sulfide stress cracking, FEA, K1SSC.

Also Purchased
Picture for 06126 UNDERSTANDING AND CONTROLLING VARIATIONS
Available for download

06126 UNDERSTANDING AND CONTROLLING VARIATIONS IN DCB TEST RESULTS

Product Number: 51300-06126-SG
ISBN: 06126 2006 CP
Author: P. Sutter, J. Leyer, H. Marchebois, C. Bosch, E. Wanzenberg, A. Kulgemeyer, B.J. Orlans-Joliet
$20.00
Picture for Effect of Crack Starter on K1ssc and Compliance for DCB Test
Available for download

51314-3896-Effect of Crack Starter on K1ssc and Compliance for DCB Test

Product Number: 51314-3896-SG
ISBN: 3896 2014 CP
Author: Keiichi Kondo
Publication Date: 2014
$0.00