51313-02229-New Copper/Copper Sulfate Reference Electrode for External Corrosion Monitoring of Buried Pipelines

Product Number: 51313-02229-SG
ISBN: 02229 2013 CP
Author: Zehbour Panossian
Publication Date: 2013
$0.00
$20.00
$20.00

The external corrosion of cathodically protected buried pipelines can be monitored by using carbon steel corrosion coupons. These coupons are installed near buried pipelines and they are electrically connected to the pipelines through test points. Coupon weight loss coupon visual and microscopic inspection AC and DC pipeline/soil potential and electrical current measurements are very important to predict the pipeline external corrosion processes. To measure AC and DC pipeline/soil potential copper/copper sulfate reference electrodes are installed near corrosion coupons to minimize IR-drop. However these reference electrodes have shown premature failures due to the diffusion of copper ions from the reference electrode through the soil toward the coupon surfaces. These ions are reduced at the carbon steel surface through a galvanic displacement reaction forming a thin copper coating on the steel surfaces which causes permanent damages to the steel coupons. To solve this problem the traditional copper/copper sulfate electrodes were modified and a new copper/copper sulfate reference electrode was developed. The modification was to replace the ceramic junction of the traditional reference electrodes by a metallic junction. This work has the objectives of describing the new reference electrode and presenting lab electrochemical test results performed to validate the new reference electrode.

The external corrosion of cathodically protected buried pipelines can be monitored by using carbon steel corrosion coupons. These coupons are installed near buried pipelines and they are electrically connected to the pipelines through test points. Coupon weight loss coupon visual and microscopic inspection AC and DC pipeline/soil potential and electrical current measurements are very important to predict the pipeline external corrosion processes. To measure AC and DC pipeline/soil potential copper/copper sulfate reference electrodes are installed near corrosion coupons to minimize IR-drop. However these reference electrodes have shown premature failures due to the diffusion of copper ions from the reference electrode through the soil toward the coupon surfaces. These ions are reduced at the carbon steel surface through a galvanic displacement reaction forming a thin copper coating on the steel surfaces which causes permanent damages to the steel coupons. To solve this problem the traditional copper/copper sulfate electrodes were modified and a new copper/copper sulfate reference electrode was developed. The modification was to replace the ceramic junction of the traditional reference electrodes by a metallic junction. This work has the objectives of describing the new reference electrode and presenting lab electrochemical test results performed to validate the new reference electrode.

Product tags
Also Purchased
Picture for 98673 THE BURIED REFERENCE ELECTRODE:
Available for download

98673 THE BURIED REFERENCE ELECTRODE: A CRITICAL LONG TERM PERFORMANCE STUDY

Product Number: 51300-98673-SG
ISBN: 98673 1998 CP
Author: Taylor Leon, Wayne Geyer
$20.00
Picture for 01297 EVALUATION OF PERMANENT REFERENCE
Available for download

01297 EVALUATION OF PERMANENT REFERENCE CELLS FOR DIRECT BURIAL APPLICATIONS

Product Number: 51300-01297-SG
ISBN: 01297 2001 CP
Author: J. Peter Ault, P.E., John Repp and John Travaglini
$20.00
Picture for Service Life Reduction Causes of Permanent Reference Electrodes
Available for download

51314-3800-Service Life Reduction Causes of Permanent Reference Electrodes

Product Number: 51314-3800-SG
ISBN: 3800 2014 CP
Author: Dmitry Sirota
Publication Date: 2014
$0.00