Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51314-3800-Service Life Reduction Causes of Permanent Reference Electrodes

Product Number: 51314-3800-SG
ISBN: 3800 2014 CP
Author: Dmitry Sirota
Publication Date: 2014
$0.00
$0.00
$0.00
Breakdown causes of cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes which placed in soil have been analysed and durability ways were revealed. Breakdown of cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes occurs because of internal electrolyte’s copper ions lack primordial shortage of copper sulfate crystals bonding of copper ions into an insoluble deposition a large area of membrane. Wrong values of coupon potentials can be conditioned by coppering process of the coupons and potential shift to positive direction by this reason.Cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes’ service life increase ways were offered.Problems which appear by an application of cupper/cupper sulfate permanent reference electrodes could be avoid to an advantage of silver-chlorine reference electrodes which deprived the most above-listed shortcomings.Using of silver-chlorine reference electrodes in soils and the “100 mV shift” protection criterion are offered for discussion. 
Breakdown causes of cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes which placed in soil have been analysed and durability ways were revealed. Breakdown of cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes occurs because of internal electrolyte’s copper ions lack primordial shortage of copper sulfate crystals bonding of copper ions into an insoluble deposition a large area of membrane. Wrong values of coupon potentials can be conditioned by coppering process of the coupons and potential shift to positive direction by this reason.Cupper/cupper sulfate (Cu/CuSO4) permanent reference electrodes’ service life increase ways were offered.Problems which appear by an application of cupper/cupper sulfate permanent reference electrodes could be avoid to an advantage of silver-chlorine reference electrodes which deprived the most above-listed shortcomings.Using of silver-chlorine reference electrodes in soils and the “100 mV shift” protection criterion are offered for discussion. 
Product tags
Also Purchased
Picture for 01297 EVALUATION OF PERMANENT REFERENCE
Available for download

01297 EVALUATION OF PERMANENT REFERENCE CELLS FOR DIRECT BURIAL APPLICATIONS

Product Number: 51300-01297-SG
ISBN: 01297 2001 CP
Author: J. Peter Ault, P.E., John Repp and John Travaglini
$20.00
Picture for 98673 THE BURIED REFERENCE ELECTRODE:
Available for download

98673 THE BURIED REFERENCE ELECTRODE: A CRITICAL LONG TERM PERFORMANCE STUDY

Product Number: 51300-98673-SG
ISBN: 98673 1998 CP
Author: Taylor Leon, Wayne Geyer
$20.00
Picture for 11047 The Fallibility of Data Using Permanent Reference Electrodes
Available for download

11047 The Fallibility of Data Using Permanent Reference Electrodes

Product Number: 51300-11047-SG
ISBN: 11047 2011 CP
Author: Robin Leigh Pawson
Publication Date: 2011
$20.00