In a recent modular construction project, severe corrosion of the gasket contact surfaces of flange
faces was found to have occurred after the flanges had been tightened. Root-cause analysis indicated
that there is a greater chance of water ingress in tightened flanges in modular construction than in stickbuilt
construction and that the longer construction period in the former can result in the severe corrosion
of flange faces observed. Therefore, in order to mitigate or prevent such corrosion in modular
construction, countermeasures should be taken. In this paper, two means of mitigating or preventing
flange face corrosion in tightened flanges (i.e., a rust preventive coating and a special spiral wound
gasket) were tested, and these tests confirmed their effectiveness.

In a recent modular construction project, severe corrosion of the gasket contact surfaces of flange
faces was found to have occurred after the flanges had been tightened. Root-cause analysis indicated
that there is a greater chance of water ingress in tightened flanges in modular construction than in stickbuilt
construction and that the longer construction period in the former can result in the severe corrosion
of flange faces observed. Therefore, in order to mitigate or prevent such corrosion in modular
construction, countermeasures should be taken. In this paper, two means of mitigating or preventing
flange face corrosion in tightened flanges (i.e., a rust preventive coating and a special spiral wound
gasket) were tested, and these tests confirmed their effectiveness.

Also Purchased
Picture for 01241 FAILURE ANALYSIS OF CRACKED REDUCER
Available for download

01241 FAILURE ANALYSIS OF CRACKED REDUCER FLANGE

Product Number: 51300-01241-SG
ISBN: 01241 2001 CP
Author: K.Habib and K.Bouresli
$20.00
Picture for 03430 Non-Invasive Measurement of Corrosion
Available for download

03430 Non-Invasive Measurement of Corrosion of Flange Sealing Surfaces

Product Number: 51300-03430-SG
ISBN: 03430 2003 CP
Author: John J. Nyholt, Frank Dodd
$20.00