A cracked reducer flange was analyzed for the cause of the failure. The flange was carefully cut in order to obtain samples for metallographic , x-ray , and Scanning Electron Microscopy (SEM) Examinations. The examinations revealed that the introduction of chloride ions in the operational service led to pitting corrosion in the inner surface of the flange. Chloride ions were probably the result of chemical contaminations, i.e., cleaning contamination during shutdown of the operation . The introduction of corrosion pits, caused unexpected load stress intensification and cracldng of the flange. Consequently, stress corrosion cracking emanated from the pits under the influence of chloride attack and operational pressure. Then the cracks propagated in a transgranular manner, in the radial direction of the flange, until the final failure occurred. Keywords: Reducer Flange, Pitting Corrosion, Stress Corrosion Cracking , Metallographic Examination, X-Ray, Scanning Electron Microscopy, Fracture roughness, and Stress Intensity Factor.
A cracked reducer flange was analyzed for the cause of the failure. The flange was carefully cut in order to obtain samples for metallographic , x-ray , and Scanning Electron Microscopy (SEM) Examinations. The examinations revealed that the introduction of chloride ions in the operational service led to pitting corrosion in the inner surface of the flange. Chloride ions were probably the result of chemical contaminations, i.e., cleaning contamination during shutdown of the operation . The introduction of corrosion pits, caused unexpected load stress intensification and cracldng of the flange. Consequently, stress corrosion cracking emanated from the pits under the influence of chloride attack and operational pressure. Then the cracks propagated in a transgranular manner, in the radial direction of the flange, until the final failure occurred. Keywords: Reducer Flange, Pitting Corrosion, Stress Corrosion Cracking , Metallographic Examination, X-Ray, Scanning Electron Microscopy, Fracture roughness, and Stress Intensity Factor.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 03053 INVESTIGATION AND ANALYSIS OF LINING FAILURE
Available for download

03053 INVESTIGATION AND ANALYSIS OF LINING FAILURE

Product Number: 51300-03053-SG
ISBN: 03053 2003 CP
Author: Bernard R. Appleman, Cynthia L. Fairfull
$20.00
Picture for 03569 MICROBIOLOGICALLY INDUCED CORROSION
Available for download

03569 MICROBIOLOGICALLY INDUCED CORROSION OF COPPER PIPING SYSTEM - FAILURE ANALYSIS

Product Number: 51300-03569-SG
ISBN: 03569 2003 CP
Author: E. M. Labuda
$20.00