Grout in failed post-tensioned tendons in Florida with varying extent of segregation was characterized as having different properties and chemistry which may promote corrosion activity. Although early repair procedures have been implemented in a bridge to remove the most severely segregated grout from some locations of the deficient tendons some concerns on future corrosion progression after initial repairs have been raised.
 

There was interest in gauging the extent to which corrosion may develop for repaired PT systems in which void spaces have been re-grouted with dissimilar grouting materials and where differences in pore water chemistry may contribute to corrosion development. This study aims to determine the extent to which corrosion of strand in dissimilar grout materials can form. The research was to identify corrosion mechanisms that may occur in tendons with ideal and deficient/partial repair conditions.
 

Grout in failed post-tensioned tendons in Florida with varying extent of segregation was characterized as having different properties and chemistry which may promote corrosion activity. Although early repair procedures have been implemented in a bridge to remove the most severely segregated grout from some locations of the deficient tendons some concerns on future corrosion progression after initial repairs have been raised.
 

There was interest in gauging the extent to which corrosion may develop for repaired PT systems in which void spaces have been re-grouted with dissimilar grouting materials and where differences in pore water chemistry may contribute to corrosion development. This study aims to determine the extent to which corrosion of strand in dissimilar grout materials can form. The research was to identify corrosion mechanisms that may occur in tendons with ideal and deficient/partial repair conditions.
 

Product tags
Also Purchased
Picture for Corrosion Failure of Post-Tensioned Tendons in Presence of Deficient Grout
Available for download

51313-02600-Corrosion Failure of Post-Tensioned Tendons in Presence of Deficient Grout

Product Number: 51313-02600-SG
ISBN: 02600 2013 CP
Author: Kingsley Lau
Publication Date: 2013
$20.00
Picture for Corrosion Evaluation of Repair-Grouted Post-Tensioned Tendons in Presence of Bleed Water
Available for download

51313-02604-Corrosion Evaluation of Repair-Grouted Post-Tensioned Tendons in Presence of Bleed Water

Product Number: 51313-02604-SG
ISBN: 02604 2013 CP
Author: Kingsley Lau
Publication Date: 2013
$20.00
Picture for Evaluating Inhibitor Performance in CO2-Saturated Erosion-Corrosion Environments
Available for download

51313-02585-Evaluating Inhibitor Performance in CO2-Saturated Erosion-Corrosion Environments

Product Number: 51313-02585-SG
ISBN: 02585 2013 CP
Author: Richard Barker
Publication Date: 2013
$20.00