Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

Use GIVING24 at checkout to save 20% on eCourses and books (some exclusions apply)!

51314-3824-Corrosivity of Dilbit and Synbit compared with Conventional Crudes under Pipeline Conditions

Product Number: 51314-3824-SG
ISBN: 3824 2014 CP
Author: Dale McIntyre
Publication Date: 2014
$0.00
$20.00
$20.00
Assertions that dilbit is extraordinarily corrosive have delayed pipeline approvals in Canada and the US. Static 65ºC laboratory autoclave corrosion tests of pipeline steels exposed to simulated produced water covered by Canadian dilbit synbit and conventional crudes all showed comparable low corrosion rates. The oils themselves in the absence of water were non-corrosive. After testing the specimens showed no evidence of hydrogen induced cracking (HIC). Rotating cylinder autoclave tests for erosion-corrosion at 65ºC with typical pipeline oil velocities show no significant difference in corrosion rates in the oils tested. Dilbit synbit and conventional crudes show similar water breakout tendency in interfacial tension (IFT) measurements. Corrosion inhibitors prevent pitting more efficiently in dilbit than in conventional crude. Tests of corrosion under deposits showed no significant difference in corrosion rate between dilbit synbit and conventional crudes.
Assertions that dilbit is extraordinarily corrosive have delayed pipeline approvals in Canada and the US. Static 65ºC laboratory autoclave corrosion tests of pipeline steels exposed to simulated produced water covered by Canadian dilbit synbit and conventional crudes all showed comparable low corrosion rates. The oils themselves in the absence of water were non-corrosive. After testing the specimens showed no evidence of hydrogen induced cracking (HIC). Rotating cylinder autoclave tests for erosion-corrosion at 65ºC with typical pipeline oil velocities show no significant difference in corrosion rates in the oils tested. Dilbit synbit and conventional crudes show similar water breakout tendency in interfacial tension (IFT) measurements. Corrosion inhibitors prevent pitting more efficiently in dilbit than in conventional crude. Tests of corrosion under deposits showed no significant difference in corrosion rate between dilbit synbit and conventional crudes.
Product tags
Also Purchased
Picture for Challenges in Analyzing ECDA Indirect Inspections Data
Available for download

51314-3815-Challenges in Analyzing ECDA Indirect Inspections Data

Product Number: 51314-3815-SG
ISBN: 3815 2014 CP
Author: Sorin Segall
Publication Date: 2014
$0.00
Picture for Investigation of Limits for UNS S17400 in H2S Containing Environments
Available for download

51314-3816-Investigation of Limits for UNS S17400 in H2S Containing Environments

Product Number: 51314-3816-SG
ISBN: 3816 2014 CP
Author: Robert Badrak
Publication Date: 2014
$0.00
Picture for Developing a Standardized Process for Cathodic Protection Current Measurement on in-service Pipeline
Available for download

51314-3821-Developing a Standardized Process for Cathodic Protection Current Measurement on in-service Pipelines

Product Number: 51314-3821-SG
ISBN: 3821 2014 CP
Author: David Williams
Publication Date: 2014
$0.00