96577 EFFECTIVE MONITORING OF NON-CHROMATE CHEMICAL TREATMENT PROGRAMS FOR REFINERY COOLING SYSTEMS USING SEWAGE WATER AS MAKE-UP

Product Number: 51300-96577-SG
ISBN: 96577 1996 CP
Author: A. D. AI-Majnouni, A. E. Jaffer
$0.00
$20.00
$20.00
Treated sewage water as make-up to the cooling tower requires novel approaches to control potential cooling water problems common to refineries besides meeting environmental regulations. An intensive field study was conducted to evaluate the effectiveness of non-chromate treatment programs. On-line cleaning of the exchangers occurred prior to instituting the new chemical treatment program. Low carbon steel corrosion rates with minimal deposition was achieved. Microbiological fouling was controlled with chlorination and non-oxidizing biocide program. Field results are presented which compare the efficacy of these proprietary treatments to control corrosion and inhibit scale and fouling. Analytical results which provide a comprehensive performance evaluation of a new non-chromate chemical treatment program are presented. Keywords: cooling tower, chromate, sewage water, corrosion, scaling, microbiological fouling, heat exchanger, phosphate, cycles of concentration, chlorination, non-oxidizing biocide.
Treated sewage water as make-up to the cooling tower requires novel approaches to control potential cooling water problems common to refineries besides meeting environmental regulations. An intensive field study was conducted to evaluate the effectiveness of non-chromate treatment programs. On-line cleaning of the exchangers occurred prior to instituting the new chemical treatment program. Low carbon steel corrosion rates with minimal deposition was achieved. Microbiological fouling was controlled with chlorination and non-oxidizing biocide program. Field results are presented which compare the efficacy of these proprietary treatments to control corrosion and inhibit scale and fouling. Analytical results which provide a comprehensive performance evaluation of a new non-chromate chemical treatment program are presented. Keywords: cooling tower, chromate, sewage water, corrosion, scaling, microbiological fouling, heat exchanger, phosphate, cycles of concentration, chlorination, non-oxidizing biocide.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96584 MONITORING REQUIREMENTS WITH REUSE WATERS
Available for download

96584 MONITORING REQUIREMENTS WITH REUSE WATERS FOR COOLING SYSTEMS

Product Number: 51300-96584-SG
ISBN: 96584 1996 CP
Author: Paul R. Puckorius
$20.00
Picture for 96579 RECLAIMED WATER FOR COOLING TOWER
Available for download

96579 RECLAIMED WATER FOR COOLING TOWER MAKE-UP: CONCERNS, MONITORING AND PROVEN TREATMENT

Product Number: 51300-96579-SG
ISBN: 96579 1996 CP
Author: David B. Ritz, Chris Spurell
$20.00
Picture for 96582 STRATEGIC PLANNING FOR AND IMPLEMENTATION
Available for download

96582 STRATEGIC PLANNING FOR AND IMPLEMENTATION OF RECLAIMED MUNICIPAL WASTE WATER AS MAKE-UP TO A REFINERY COOLING SYSTEM

Product Number: 51300-96582-SG
ISBN: 96582 1996 CP
Author: W.R. Francis, J. J. Mazur, N. M. Rao
$20.00