11049 Retrofitting Concentric Circles MMO Anodes for Impressed Current Cathodic Protection System in Tank Farm

Product Number: 51300-11049-SG
ISBN: 11049 2011 CP
Author: Saad H. AL-Khaldi, Prasanta Kumar Mukhopadhyay and Ravi Shankar Siriki
Publication Date: 2011
$0.00
$20.00
$20.00
Providing adequate Cathodic Protection (C.P) to existing tank bottoms in a refinery with many underground structures always pose a challenge. As the original C.P system in the refinery had been quite old and ineffective, a revamping of the C.P system for the refinery tanks and underground piping was carried out which excluded the double bottom tanks. However subsequently due to corrosion of the second bottom of the double bottomed tank, there was an opportunity and a challenge to include this tank in the revamped C.P. system. The paper describes these challenges in providing MMO anode system consisting of a series of concentric loops in a narrow 300mm space between the tank bottom and a polyethylene liner placed under the new bottom constructed. The concentric loops were closely spaced to provide desired current distribution and to optimize the “throwing power” of the anodes. After commissioning the C.P System, the protection level as measured by the permanent Cu/CuSO4 half cell and the polarization coupon placed under the tank bottom met the protection criteria as set in NACE standard RP0193-2001. This was done at a fraction of the energy required for protection of a similar tank using conventional system. Keywords: Cathodic Protection (C.P), Double Bottomed Storage Tanks, Polyethylene liner, Concentric circles, MMO, Cu / CuSO4 half cell, polarization coupon, NACE.
Providing adequate Cathodic Protection (C.P) to existing tank bottoms in a refinery with many underground structures always pose a challenge. As the original C.P system in the refinery had been quite old and ineffective, a revamping of the C.P system for the refinery tanks and underground piping was carried out which excluded the double bottom tanks. However subsequently due to corrosion of the second bottom of the double bottomed tank, there was an opportunity and a challenge to include this tank in the revamped C.P. system. The paper describes these challenges in providing MMO anode system consisting of a series of concentric loops in a narrow 300mm space between the tank bottom and a polyethylene liner placed under the new bottom constructed. The concentric loops were closely spaced to provide desired current distribution and to optimize the “throwing power” of the anodes. After commissioning the C.P System, the protection level as measured by the permanent Cu/CuSO4 half cell and the polarization coupon placed under the tank bottom met the protection criteria as set in NACE standard RP0193-2001. This was done at a fraction of the energy required for protection of a similar tank using conventional system. Keywords: Cathodic Protection (C.P), Double Bottomed Storage Tanks, Polyethylene liner, Concentric circles, MMO, Cu / CuSO4 half cell, polarization coupon, NACE.
Product tags
Also Purchased
Picture for 00829 TECHNIQUES FOR ACCURATE EVALUATION OF
Available for download

00829 TECHNIQUES FOR ACCURATE EVALUATION OF ABOVEGROUND STORAGE TANK CATHODIC PROTECTION SYSTEM EFFECTIVENESS

Product Number: 51300-00829-SG
ISBN: 00829 2000 CP
Author: Tim Whited
$20.00