Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

10069 Finding and Determining the Cause of External Corrosion on Coated and Cathodically Protected Pipelines

Product Number: 51300-10069-SG
ISBN: 10069 2010 CP
Author: Richard Norsworthy
Publication Date: 2010
$0.00
$20.00
$20.00
Direct Assessment is a very good method of determining if external corrosion is a potential problem on a coated and cathodically protected pipeline. The type of coating can be critical in finding where and if external corrosion is a problem. Many times external corrosion can not be located through over the line surveys because cathodic protection potentials indicate adequate protection, therefore there should be no external corrosion, yet internal line inspection (ILI) tools find corrosion. Many times the cause and age of the corrosion are not properly evaluated when performing direct assessment of these pipelines. This paper will discuss common sense evaluation methods for determining why external corrosion still exists and in some cases continues even with apparent adequate cathodic protection.

KEY WORDS: Cathodic protection, CP shielding, Coating Deterioration, ECDA, DCVG, ACVG
Direct Assessment is a very good method of determining if external corrosion is a potential problem on a coated and cathodically protected pipeline. The type of coating can be critical in finding where and if external corrosion is a problem. Many times external corrosion can not be located through over the line surveys because cathodic protection potentials indicate adequate protection, therefore there should be no external corrosion, yet internal line inspection (ILI) tools find corrosion. Many times the cause and age of the corrosion are not properly evaluated when performing direct assessment of these pipelines. This paper will discuss common sense evaluation methods for determining why external corrosion still exists and in some cases continues even with apparent adequate cathodic protection.

KEY WORDS: Cathodic protection, CP shielding, Coating Deterioration, ECDA, DCVG, ACVG
Product tags
Also Purchased
Picture for 11128 Interpretation of Indirect Inspections Data in the ECDA Process
Available for download

11128 Interpretation of Indirect Inspections Data in the ECDA Process

Product Number: 51300-11128-SG
ISBN: 2011 11128 CP
Author: Sorin M. Segall, R. A. Gummow and John Shore
Publication Date: 2011
$20.00
Picture of 06188 DEVELOPMENT OF ECDA CRITERIA FOR PRIORITIZATION OF INDICATIONS
Available for download

06188 DEVELOPMENT OF ECDA CRITERIA FOR PRIORITIZATION OF INDICATIONS

Product Number: 51300-06188-SG
ISBN: 06188 2006 CP
Author: Daphne D'Zurko, Oliver C. Moghissi, James Patrick McKinney and Mark E. Orazem
$20.00
Picture for 09116  Causes of External Corrosion on Coated and Cathodically Protected Pipelines
Available for download

09116 Causes of External Corrosion on Coated and Cathodically Protected Pipelines

Product Number: 51300-09116-SG
ISBN: 09116 2009 CP
Author: Richard Norsworthy
Publication Date: 2009
$20.00