08508 MIC in Fire Sprinkler Systems - Field Observations and Data

Field observations and laboratory test results for several different fire sprinkler failure investigations conducted in the past several years in a variety of locations across the US. Field experience with assessment data, basis for diagnosis, mitigation and rehabilitation recommendations to prevent recurrence are presented.

Product Number: 51300-08508-SG
ISBN: 08508 2008 CP
Author: Ockert J. Van Der Schijff
Publication Date: 2008
$0.00
$20.00
$20.00

Microbiologically Influenced Corrosion (MIC) has been implicated as the root-cause for the corrosion failure of a large number of wet, dry, and pre-action fire sprinkler systems, often resulting in costly repairs and litigation. This paper presents field observations and laboratory test results for several different fire sprinkler failure investigations conducted over the course of the past several years in a variety of locations across the US. Field experience with assessment data, basis for diagnosis, mitigation and rehabilitation recommendations to prevent recurrence are presented. Aggregated results of laboratory microbiological culturing of deposit samples collected from affected sprinkler systems are presented and discussed. Conclusions drawn from these results regarding the part that MIC plays in the corrosion failure of the various types of sprinklers systems are presented and discussed.

Keywords: MIC, sprinkler systems, field tests, lab tests, corrosion failure

 

Microbiologically Influenced Corrosion (MIC) has been implicated as the root-cause for the corrosion failure of a large number of wet, dry, and pre-action fire sprinkler systems, often resulting in costly repairs and litigation. This paper presents field observations and laboratory test results for several different fire sprinkler failure investigations conducted over the course of the past several years in a variety of locations across the US. Field experience with assessment data, basis for diagnosis, mitigation and rehabilitation recommendations to prevent recurrence are presented. Aggregated results of laboratory microbiological culturing of deposit samples collected from affected sprinkler systems are presented and discussed. Conclusions drawn from these results regarding the part that MIC plays in the corrosion failure of the various types of sprinklers systems are presented and discussed.

Keywords: MIC, sprinkler systems, field tests, lab tests, corrosion failure

 

Also Purchased
Picture for 00653 REMEDIATION OF CORROSION PROBLEMS
Available for download

00653 REMEDIATION OF CORROSION PROBLEMS INSIDE FIRE SPRINKLER SYSTEM PIPING

Product Number: 51300-00653-SG
ISBN: 00653 2000 CP
Author: S. Steven Carl
$20.00
Picture for 00401 MICROBIOLOGICALLY INFLUENCED CORROSION
Available for download

00401 MICROBIOLOGICALLY INFLUENCED CORROSION IN FIRE PROTECTION SPRINKLER SYSTEMS

Product Number: 51300-00401-SG
ISBN: 00401 2000 CP
Author: Daniel H. Pope and Rebecca M. Pope
$20.00