08302 Arresting and Preventing Corrosion of Steel in Concrete

Product Number: 51300-08302-SG
ISBN: 08302 2008 CP
Author: Nigel Davison, Adrian Roberts, and Gareth K. Glass
Publication Date: 2008
Industry: Highways & Bridges
$0.00
$20.00
$20.00
Corrosion of steel reinforcement is a major factor affecting the durability of reinforced concrete structures. To address this problem an improved electrochemical treatment consisting of two phases has been developed. Firstly a high current is briefly driven to the steel to arrest corrosion. In the process corroding sites are moved from the steel to an installed anode system. This first phase lasts about 1 week. Galvanic protection is then provided. This is low maintenance and requires no user intervention to function. A single anode system consisting of a hybrid of impressed current and sacrificial technologies is installed to deliver the protection current in both phases. The anode system will typically contain enough charge to provide galvanic protection current for 50 years. This depends on the aggressive nature of the environment. The two phase treatment has now been applied to more than 10 structures around the world including bridges, car parks, marine structures and buildings and the first laboratory trial in heavily chloride contaminated concrete continues to deliver outstanding performance. Monitoring has been tailored to meet end user requirements and in every case tested steel passivity has been achieved.
Corrosion of steel reinforcement is a major factor affecting the durability of reinforced concrete structures. To address this problem an improved electrochemical treatment consisting of two phases has been developed. Firstly a high current is briefly driven to the steel to arrest corrosion. In the process corroding sites are moved from the steel to an installed anode system. This first phase lasts about 1 week. Galvanic protection is then provided. This is low maintenance and requires no user intervention to function. A single anode system consisting of a hybrid of impressed current and sacrificial technologies is installed to deliver the protection current in both phases. The anode system will typically contain enough charge to provide galvanic protection current for 50 years. This depends on the aggressive nature of the environment. The two phase treatment has now been applied to more than 10 structures around the world including bridges, car parks, marine structures and buildings and the first laboratory trial in heavily chloride contaminated concrete continues to deliver outstanding performance. Monitoring has been tailored to meet end user requirements and in every case tested steel passivity has been achieved.
Product tags
Also Purchased
Picture for 08303 Cathodic Protection at Durrat Al Bahrain
Available for download

08303 Cathodic Protection at Durrat Al Bahrain

Product Number: 51300-08303-SG
ISBN: 08303 2008 CP
Author: Rod Callon
Publication Date: 2008
$20.00
Picture for 08300 Implementation of Advanced Electronic Techniques for Remote Monitoring of Cathodic Protection
Available for download

08300 Implementation of Advanced Electronic Techniques for Remote Monitoring of Cathodic Protection, Scour and Environmental Conditions for Marine Bridges in Florida

Product Number: 51300-08300-SG
ISBN: 08300 2008 CP
Author: Richard J. Kessler, Rodney G. Powers, and Ivan R. Lasa
Publication Date: 2008
$20.00
Picture for 08311 Corrosion of Epoxy Coated Rebar in Cracked Marine Substructure Concrete
Available for download

08311 Corrosion of Epoxy Coated Rebar in Cracked Marine Substructure Concrete

Product Number: 51300-08311-SG
ISBN: 08311 2008 CP
Author: Kingsley Lau, Rodney G. Powers, and Alberto A. Sagüés
Publication Date: 2008
$20.00