Search
Filters
Close

07389 Multi-Linear-Reference-Electrode for Localized Corrosion Monitoring

Product Number: 51300-07389-SG
ISBN: 07389 2007 CP
Author: Marco Ormellese, Luciano Lazzari, and Elena Redaelli
Publication Date: 2007
$0.00
$20.00
$20.00
In order to monitor in-time the occurrence of localized corrosion in concrete structures (viaduct, aqueduct, PCCP, pre-stressed and post-tensioned structures), a multi-reference electrode was proposed and studied, consisting of a series of continuous metallic wires able to measure the potential of carbon steel rebars and tendons. Because chloride-induced pitting may provoke hydrogen embrittlement of high strength steel, an early detection of corrosion initiation is very important to avoid such brittle fracture. Laboratory tests on mortar samples simulating post-tensioned tendons corrosion, induced by chlorides, confirmed the effectiveness of this new reference electrode. For its application to PCCP, a FEM analysis was performed to determine the optimal electrode size as a function of pipe diameter, concrete cover and soil resistivity. Results are reported and discussed.
In order to monitor in-time the occurrence of localized corrosion in concrete structures (viaduct, aqueduct, PCCP, pre-stressed and post-tensioned structures), a multi-reference electrode was proposed and studied, consisting of a series of continuous metallic wires able to measure the potential of carbon steel rebars and tendons. Because chloride-induced pitting may provoke hydrogen embrittlement of high strength steel, an early detection of corrosion initiation is very important to avoid such brittle fracture. Laboratory tests on mortar samples simulating post-tensioned tendons corrosion, induced by chlorides, confirmed the effectiveness of this new reference electrode. For its application to PCCP, a FEM analysis was performed to determine the optimal electrode size as a function of pipe diameter, concrete cover and soil resistivity. Results are reported and discussed.
Product tags
Also Purchased
Picture for 98673 THE BURIED REFERENCE ELECTRODE:
Available for download

98673 THE BURIED REFERENCE ELECTRODE: A CRITICAL LONG TERM PERFORMANCE STUDY

Product Number: 51300-98673-SG
ISBN: 98673 1998 CP
Author: Taylor Leon, Wayne Geyer
$20.00
Picture for New Copper/Copper Sulfate Reference Electrode for External Corrosion Monitoring of Buried Pipelines
Available for download

51313-02229-New Copper/Copper Sulfate Reference Electrode for External Corrosion Monitoring of Buried Pipelines

Product Number: 51313-02229-SG
ISBN: 02229 2013 CP
Author: Zehbour Panossian
Publication Date: 2013
$20.00
Picture for 09449 Multi-Reference-Electrode for Monitoring of Localized Corrosion in Concrete Structures
Available for download

09449 Multi-Reference-Electrode for Monitoring of Localized Corrosion in Concrete Structures

Product Number: 51300-09449-SG
ISBN: 09449 2009 CP
Author: Marco Ormellese, Pietro Pedeferri and Luciano Lazzari
Publication Date: 2009
$20.00