Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

07242 Evaluation of a Chloride Contaminated Basement in a Power Plant

Product Number: 51300-07242-SG
ISBN: 07242 2007 CP
Author: Erika Sanchez, Miguel Sanchez, Oladis de Rincon, and Sebastian Delgado
Publication Date: 2007
$0.00
$20.00
$20.00
Many repairs on structures are performed without previous diagnosis and inspection from a structuralcorrosion point of view enhancing the damages due to the creation of active areas which can cause catastrophic accidents and increasing costs from ineffective maintenance and even shutdown of the structure. This paper presents an evaluation and repair diagnosis from a structural corrosion point of view of a basement located in a Power Unit of a Petrochemical Plant. This basement is continuously exposed to floods and stagnation from Maracaibo’s lake water. This water is very aggressive since it contains chlorides, foam and traces of oils. Due to structural problems, repairs were done urgently without any previous inspection. An inspection was carried out after the repairs were completed in order to evaluate them and elaborate a repair guideline. From this study, it was concluded that the earlier repairs didn’t meet durability criteria and new repairs are suggested.
Many repairs on structures are performed without previous diagnosis and inspection from a structuralcorrosion point of view enhancing the damages due to the creation of active areas which can cause catastrophic accidents and increasing costs from ineffective maintenance and even shutdown of the structure. This paper presents an evaluation and repair diagnosis from a structural corrosion point of view of a basement located in a Power Unit of a Petrochemical Plant. This basement is continuously exposed to floods and stagnation from Maracaibo’s lake water. This water is very aggressive since it contains chlorides, foam and traces of oils. Due to structural problems, repairs were done urgently without any previous inspection. An inspection was carried out after the repairs were completed in order to evaluate them and elaborate a repair guideline. From this study, it was concluded that the earlier repairs didn’t meet durability criteria and new repairs are suggested.
Product tags
Also Purchased
Picture for 07223 Advanced Materials and Coatings for Corrosion Intensive Components at Water Treatment Plants
Available for download

07223 Advanced Materials and Coatings for Corrosion Intensive Components at Water Treatment Plants

Product Number: 51300-07223-SG
ISBN: 07223 2007 CP
Author: Larry D. Stephenson and Ashok Kumar
Publication Date: 2007
$20.00
Picture for 07237 Long-Term Marine Atmospheric Corrosion Testing Experiences
Available for download

07237 Long-Term Marine Atmospheric Corrosion Testing Experiences

Product Number: 51300-07237-SG
ISBN: 07237 2007 CP
Author: Robert M. Kain, S.J. Pikul, and Bopinder S. Phull
Publication Date: 2007
$20.00
Picture for 07255 Relations between Seawater Ennoblement Selectivity and Passive Film Semiconductivity on Ni-Cr-
Available for download

07255 Relations between Seawater Ennoblement Selectivity and Passive Film Semiconductivity on Ni-Cr-Mo Alloys

Product Number: 51300-07255-SG
ISBN: 07255 2007 CP
Author: Farrel J. Martin, Edward J. Lemieux, Stephen C. Dexter, and Matthew Strom
Publication Date: 2007
$20.00