Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

03060 HYDROGEN SULFIDE AND MICROBIOLOGICALLY INFLUENCED CORROSION OF CONCRETE, STEEL AND DUCTILE IRON IN WASTE WATER FACILITIES

Corrosion and structural deterioration due to microbiologically influenced sulfate reduction and hydrogen sulfide gas oxidation to sulfuric acid are responsible for much of the expense related to santiatry sewage collection systems.  This paper explains the mechanism of this biologically induced corrosion, its consequence, and methods to mediate it.

Product Number: 51300-03060-SG
ISBN: 03060 2003 CP
Author: Kenneth B. Tator P.E.
Publication Date: 2003
Industry: Water/Wastewater
$0.00
$20.00
$20.00

In the United States, sanitary sewage collection systems consist of one of the largest capital investments in the infrastructure. In 2001, Congress appropriated $1.35 billion for wastewater infrastructure improvements, but the actual need is estimated to be approximately 9 times this amount, at $12 billion per year. Corrosion and structural deterioration due to microbiologically influenced sulfate reduction and hydrogen sulfide gas oxidation to sulfuric acid are responsible for much of this expense. This paper explains the mechanism of this biologically induced corrosion, its consequence, and methods to mediate it.

Keywords:  sanitary sewage collection, corrosion, mic, hydrogen sulfide

In the United States, sanitary sewage collection systems consist of one of the largest capital investments in the infrastructure. In 2001, Congress appropriated $1.35 billion for wastewater infrastructure improvements, but the actual need is estimated to be approximately 9 times this amount, at $12 billion per year. Corrosion and structural deterioration due to microbiologically influenced sulfate reduction and hydrogen sulfide gas oxidation to sulfuric acid are responsible for much of this expense. This paper explains the mechanism of this biologically induced corrosion, its consequence, and methods to mediate it.

Keywords:  sanitary sewage collection, corrosion, mic, hydrogen sulfide

PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Also Purchased
Picture for 02451 MIC ON STAINLESS STEELS IN WASTEWATER...
Available for download

02451 MIC ON STAINLESS STEELS IN WASTEWATER TREATMENT PLANTS FIELD TESTS AND A RISK ASSESSMENT

Product Number: 51300-02451-SG
ISBN: 02451 2002 CP
Author: A. Iversen
$20.00
Picture for 03056 Zero (VOC) Structural Epoxy Rehabilitation
Available for download

03056 Zero (VOC) Structural Epoxy Rehabilitation of Steel and Concrete Tanks, Pipes and Structures

Product Number: 51300-03056-SG
ISBN: 03056 2003 CP
Author: Danny R. Warren
$20.00