51314-3863-The Effect of Buffering Capacity on HIC Behavior for FFP Evaluation

Product Number: 51314-3863-SG
ISBN: 3863 2014 CP
Author: Daisuke Mizuno
Publication Date: 2014
$0.00
$0.00
$0.00
Hydrogen Induced Cracking (HIC) is a major issue of line pipe steels exposed to sour environments. In general 5.0 wt% NaCl and 0.5 wt% CH3COOH solution with 0.1 MPa H2S provided by NACE TM0284 as solution A is used to evaluate the HIC resistance of steel plates and pipe products. However in many cases the test condition is too severe compared to the actual field conditions. Therefore Fit-For-Purpose (FFP) HIC evaluation method has been the subject of considerable investigations in recent years. High Strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) is investigating an appropriate test solution for FFP HIC test from the viewpoint of pH stability because pH is a significant factor affecting HIC behavior along with H2S concentration. In our previous work we proposed the test solution that provides high buffering capacity due to high concentration of acetic acid and sodium acetate. In this study HIC test were carried out in the several buffer solutions and the effect of pH shift on HIC behavior was investigated. The pH stability of high acetic acid and sodium acetate solution under low H2S partial pressure is also discussed because FFP HIC test tends to require long test duration in mildly sour environments (low H2S and high pH). 
Hydrogen Induced Cracking (HIC) is a major issue of line pipe steels exposed to sour environments. In general 5.0 wt% NaCl and 0.5 wt% CH3COOH solution with 0.1 MPa H2S provided by NACE TM0284 as solution A is used to evaluate the HIC resistance of steel plates and pipe products. However in many cases the test condition is too severe compared to the actual field conditions. Therefore Fit-For-Purpose (FFP) HIC evaluation method has been the subject of considerable investigations in recent years. High Strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) is investigating an appropriate test solution for FFP HIC test from the viewpoint of pH stability because pH is a significant factor affecting HIC behavior along with H2S concentration. In our previous work we proposed the test solution that provides high buffering capacity due to high concentration of acetic acid and sodium acetate. In this study HIC test were carried out in the several buffer solutions and the effect of pH shift on HIC behavior was investigated. The pH stability of high acetic acid and sodium acetate solution under low H2S partial pressure is also discussed because FFP HIC test tends to require long test duration in mildly sour environments (low H2S and high pH). 
Product tags
Also Purchased
Picture for Proposal of HIC Test Solution with Buffer Capacity in NACE Standard TM0284
Available for download

51313-02289-Proposal of HIC Test Solution with Buffer Capacity in NACE Standard TM0284

Product Number: 51313-02289-SG
ISBN: 02289 2013 CP
Author: Takuya Hara
Publication Date: 2013
$20.00
Picture for Comparison of Anaerobic Biocorrosion Mechanisms for Different Systems
Available for download

51314-3878-Comparison of Anaerobic Biocorrosion Mechanisms for Different Systems

Product Number: 51314-3878-SG
ISBN: 3878 2014 CP
Author: Tingyue Gu
Publication Date: 2014
$0.00
Picture for Localized Corrosion Initiation of Carbon Steel in a CO2 Environment
Available for download

51314-3880-Localized Corrosion Initiation of Carbon Steel in a CO2 Environment

Product Number: 51314-3880-SG
ISBN: 3880 2014 CP
Author: Xin Gao
Publication Date: 2014
$0.00