Ferrite measurements are used during welding procedures on duplex stainless steel. We studied the effects on the measured ferrite contents of (1) grid size, (2) number of fields and (3) measurement locations.
When duplex stainless steel (DSS) is applied to welded components, ferrite measurement with manual point count according to ASTM(1) E562 is often used during welding procedure qualification as heat affected zone (HAZ) of the weld tends to have high ferrite content. For this measurement method, there are several testing variables and it seems that standard testing variables are not used for ferrite measurements performed by various fabricators. In this paper, the effects of three major variables described in ASTM E562, which were the grid size i.e. number of testing points in a grid, number of fields and measurement locations, on the measured ferrite contents were studied. Also, ferrite measurement with automatic image analysis according to ASTM E1245 was performed across the fusion line of the weld to compare the ferrite content measured by manual point count according to ASTM E562. In addition to the ferrite measurement, pitting corrosion test according to ASTM G48, Method A was performed on the same sample as the one used for ferrite measurement in order to see where in the weld pitting corrosion occurs. The results have suggested a necessity of establishment of standardized testing variables to be used for ferrite measurement with manual point count according to ASTM E562.
Key words: Duplex Stainless Steel, Welding, Ferrite Content, Point Count, ASTM E562, Image Analysis
Metallurgical investigations on a welded sample of 25% Cr super duplex stainless steel (UNS S32750) from a vessel that had operated above 300-350°C (570-660°F) for six months, resulting in brittle fracture.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
In this study, welding trials were performed on 22% Cr duplex stainless steel UNS S32205 corner joints with different wall thickness similar to the top plate and tubesheet plate joint configuration used in a fin fan cooler header box.
The aim of this paper is to find a correlation between nitride content/distribution and properties of two of the largely adopted Duplex Stainless Steel (DSS), UNS* S32205 and UNS S32750. *Unified Numbering System