Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

Selection And Optimization Of Cathodic Protection Test Posts Used Or Necessary To Adequately Verify The Performance Of Cathodic Protection Systems In Annual Surveys

Product Number: 51321-17011-SG
Author: Craig Stevenson; Len J Krissa; Keith Parker; Alfonso Garcia Rojas; Rob Floria
Publication Date: 2021
$0.00
$20.00
$20.00

It is common practice for hazardous product pipeline operators to schedule physical cathodic protection (CP) pipe-to-soil (p/s) potential measurements from every available test post on all pipelines annually. Historical data confirms that when the cathodic system output remains consistent; protection levels will typically not vary significantly from year to year. Such conventional annual CP survey practice is not mandated by North American standards or codes but is rather part of the integrity management process. The practice of annual conventional test point measurement carries a high labor cost and may only achieve marginal value in the performance assessment of a cathodic protection system and overall pipeline integrity. Effective evaluation of
annual CP system performance can be accomplished without necessarily collecting data from every test post, every year. It can be achieved by taking a proactive/performance based external corrosion prevention (ECP) management approach that is aligned with other pipeline integrity programs, and utilizes all available relevant information. This paper presents a concept and methodology on optimising cathodic protection field data collection in alignment with a comprehensively progressive and proactive performance based ECP program to maintain pipeline safety.



It is common practice for hazardous product pipeline operators to schedule physical cathodic protection (CP) pipe-to-soil (p/s) potential measurements from every available test post on all pipelines annually. Historical data confirms that when the cathodic system output remains consistent; protection levels will typically not vary significantly from year to year. Such conventional annual CP survey practice is not mandated by North American standards or codes but is rather part of the integrity management process. The practice of annual conventional test point measurement carries a high labor cost and may only achieve marginal value in the performance assessment of a cathodic protection system and overall pipeline integrity. Effective evaluation of
annual CP system performance can be accomplished without necessarily collecting data from every test post, every year. It can be achieved by taking a proactive/performance based external corrosion prevention (ECP) management approach that is aligned with other pipeline integrity programs, and utilizes all available relevant information. This paper presents a concept and methodology on optimising cathodic protection field data collection in alignment with a comprehensively progressive and proactive performance based ECP program to maintain pipeline safety.



Also Purchased
Picture for Case Study of AC Interference on 20 km Buried Pipeline: Field Test and Mitigation Design
Available for download

51313-02424-Case Study of AC Interference on 20 km Buried Pipeline: Field Test and Mitigation Design

Product Number: 51313-02424-SG
ISBN: 02424 2013 CP
Author: Zitao Jiang
Publication Date: 2013
$20.00
Picture for 97604 Corrsion Data Survey: The Next Generation
Available for download

97604 Corrsion Data Survey: The Next Generation

Product Number: 51300-97604-SG
ISBN: 97604 1997 CP
Author: Bijan Mashayekhi, Charles P. Sturrock, Carole D. Flanigan
$20.00