Save 20% on select titles with code HIDDEN24 - Shop The Sale Now
Corrosion prevention and control for equipment is a costly and decreasingly effective activity for the Air Force, especially under scenarios to austere locations. One concept for remedy is a modular shelter, powered with mobile generators using integrated energy sources to reduce operational costs.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
During the rebuilding after hurricane Katrina hit the Gulf Coast in 2005, construction inspectors in coastal areas began noticing that the galvanized connectors being used were already rusting before the framing was complete. These were the same connectors, such as hurricane straps, joist hangers, beam hangers, and hurricane ties, which are easily seen beneath the elevated houses along the shoreline. Even on the construction projects that specified stainless steel connectors, inspectors could see tarnishing before the framing was complete.
Spent nuclear fuel (SNF) is currently stored in stainless steel dry storage canisters (DSCs) contained within concrete cask systems with passive ambient air cooling. These systems are emplaced, either horizontally or vertically, at independent spent fuel storage installations (ISFSIs), located at utility reactor sites. The ambient air introduces moisture, aerosolized salt particles, and dust to the canister surfaces. The composition of the aerosols depends on geographical factors, such as proximity to the ocean,industrial area, rural areas, and transportation corridors that use road salt for winterization.
Most effective and latest technology in corrosion prevention for protection of boiler systems, turbines, pumps, storage tanks, heat recovery steam generator systems, generators, and piping systems. Protection of the system is based on “temporary” corrosion inhibitors.
The most dangerous phrase in business, “We’ve always done it that way”, has never been more apt. It cannot be assumed that these linings, with proven track record in storage and processing fossil fuels, will provide the same level of asset protection in biofuels storage and biorefining processes. Likewise, the use of “generic” equivalents offers greater risks as the technology used does not define the performance.
Carbon capture and storage (CCS) or utilisation (CCU) of the captured carbon dioxide (CO2) are tools for reducing global carbon emissions, and to combat climate change both are required. According to the IEA1, in 2021, the global capacity of CCS grew by 48%i, showing that this technology is becoming more popular to meet sustainability targets.
This standard addresses initial inspection of the tubular goods and accessories prior to coating, surface preparation, coatingapplication,coatinginspection,coupling/connectionmake-up,qualitycontrol,handling,storage,shipping,and marking.
Cloud computing provides a reliable and robust infrastructure for users to remotely store and access huge amount of data. However, data integrity in the cloud is a major security concern for data owners no longer physically possess their sensitive data. To mitigate this challenge, remote data integrity has been proposed as a mechanism to enable data owners to verify the correctness of their outsourced data. The remote verification process needs to be done with reduced communication, computation, and storage overhead.
Guidelines to minimize acid corrosion problems -general corrosion, pitting, stress cracking. Preparation of the well, preparation and injection of the acid, clean-up of the well. Historical Document 1973
Results are described of sigma phase embrittlement assessments performed at three different refineries and mainly involving regenerator cyclones at fluidized catalytic cracking units (FCCU) but also including regenerator cyclones hanger rods and a regenerator flue gas line.
HISTORICAL DOCUMENT. Qualifying and controlling the quality of plant-applied, single-layer fusion-bonded epoxy (FBE) coatings to the external surfaces of carbon steel pipe. Proper application, inspection and repair.
NOTE: NACE SP0394-2013—Editorial corrections were made to Table 3 and Table 4 in 2018-04-04.