Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51313-02544-Prediction and Monitoring of Scaling and Corrosion In pH Adjusted Geothermal Brine Solutions

Product Number: 51313-02544-SG
ISBN: 02544 2013 CP
Author: Keith Lichti
Publication Date: 2013
$0.00
$20.00
$20.00

The risk of voluminous silica scaling limits many geothermal energy plants to steam and brine separation temperatures above the saturation limit for silica in the separated brine. The impact of these limits are compounded in the face of demand for secondary heat extraction using binary plant that can significantly increase energy efficiency from geothermal fluids. Options for additional energy extraction include increase in pH to increase the solubility limit for silica and decrease in pH to delay the time for onset of polymerisation reactions for colloidal silica sufficient to allow reinjection to a reservoir where elevated temperature will lower the silica saturation index. These two scale control methods can have significant impact on localised corrosion in chloride rich brines. The scaling and corrosion risks can be modelled theoretically to predict ideal conditions for enhanced energy production with minimal risk of corrosion however prudent operators can benefit from confirmation testing of scaling and corrosion risks in pilot plant that mimic planned operating conditions. This paper will outline the processes for theoretical predictions of the risk of scaling and corrosion under pH adjusted conditions in typical New Zealand geothermal brines and describe test results for an example pilot plant.

The risk of voluminous silica scaling limits many geothermal energy plants to steam and brine separation temperatures above the saturation limit for silica in the separated brine. The impact of these limits are compounded in the face of demand for secondary heat extraction using binary plant that can significantly increase energy efficiency from geothermal fluids. Options for additional energy extraction include increase in pH to increase the solubility limit for silica and decrease in pH to delay the time for onset of polymerisation reactions for colloidal silica sufficient to allow reinjection to a reservoir where elevated temperature will lower the silica saturation index. These two scale control methods can have significant impact on localised corrosion in chloride rich brines. The scaling and corrosion risks can be modelled theoretically to predict ideal conditions for enhanced energy production with minimal risk of corrosion however prudent operators can benefit from confirmation testing of scaling and corrosion risks in pilot plant that mimic planned operating conditions. This paper will outline the processes for theoretical predictions of the risk of scaling and corrosion under pH adjusted conditions in typical New Zealand geothermal brines and describe test results for an example pilot plant.

Product tags
Also Purchased
Picture for Corrosion and Scaling in Wet Scrubbing Equipment of Superheated Geothermal Well IDDP-1 in Iceland
Available for download

51313-02556-Corrosion and Scaling in Wet Scrubbing Equipment of Superheated Geothermal Well IDDP-1 in Iceland

Product Number: 51313-02556-SG
ISBN: 02556 2013 CP
Author: Sigrun Karlsdottir
Publication Date: 2013
$20.00
Picture for Corrosion Testing Downhole in Sour High Temperature Geothermal Well in Iceland
Available for download

51313-02550-Corrosion Testing Downhole in Sour High Temperature Geothermal Well in Iceland

Product Number: 51313-02550-SG
ISBN: 02550 2013 CP
Author: Sigrun Karlsdottir
Publication Date: 2013
$20.00
Picture for Scaling and Corrosion Behavior of Metallic Materials after Long-term Exposure to the Geothermal Flui
Available for download

51316-7644-Scaling and Corrosion Behavior of Metallic Materials after Long-term Exposure to the Geothermal Fluid of the North German Basin

Product Number: 51316-7644-SG
ISBN: 7644 2016 CP
Author: Helmuth Sarmiento Klapper
Publication Date: 2016
$20.00