The subsea flow lines of an oilfield located offshore Norway were at risk of corrosion due to several factors. Firstly the flow lines contained high levels of CO2 which resulted in general and pitting corrosion problems. In addition the oil wells produced significant amount of solids and in areas where these solids accumulate there was the potential for under corrosion to occur. Finally there was evidence that the welds within the pipeline were corroding preferentially. Therefore a corrosion inhibitor was required which could mitigate all the forms of corrosion present in the flow lines. To qualify an inhibitor for this application several environmentally acceptable corrosion inhibitors were developed. This paper details the test work performed to qualify a new corrosion inhibitor for this field. The inhibitors were evaluated in numerous tests including kettle test rotating cylinder electrode test HP autoclave under deposit corrosion tests and weldment corrosion test.

The subsea flow lines of an oilfield located offshore Norway were at risk of corrosion due to several factors. Firstly the flow lines contained high levels of CO2 which resulted in general and pitting corrosion problems. In addition the oil wells produced significant amount of solids and in areas where these solids accumulate there was the potential for under corrosion to occur. Finally there was evidence that the welds within the pipeline were corroding preferentially. Therefore a corrosion inhibitor was required which could mitigate all the forms of corrosion present in the flow lines. To qualify an inhibitor for this application several environmentally acceptable corrosion inhibitors were developed. This paper details the test work performed to qualify a new corrosion inhibitor for this field. The inhibitors were evaluated in numerous tests including kettle test rotating cylinder electrode test HP autoclave under deposit corrosion tests and weldment corrosion test.

Product tags
Also Purchased
Picture for Effect of Temperature on Crevice Corrosion Susceptibility of Nickel Alloys for Nuclear Repositories
Available for download

51313-02504-Effect of Temperature on Crevice Corrosion Susceptibility of Nickel Alloys for Nuclear Repositories

Product Number: 51313-02504-SG
ISBN: 02504 2013 CP
Author: Martin Rodriguez
Publication Date: 2013
$20.00
Picture for Coating Failure Incidents on the Norwegian Continental Shelf Since the Introduction of NORSOK M-501
Available for download

51313-02500-Coating Failure Incidents on the Norwegian Continental Shelf Since the Introduction of NORSOK M-501

Product Number: 51313-02500-SG
ISBN: 02500 2013 CP
Author: Ole Knudsen
Publication Date: 2013
$20.00
Picture for Best Practices for Microbial Control in Small and Medium Sized Cooling Towers
Available for download

51313-02491-Best Practices for Microbial Control in Small and Medium Sized Cooling Towers

Product Number: 51313-02491-SG
ISBN: 02491 2013 CP
Author: Christine McInnis
Publication Date: 2013
$20.00