Search
Filters
Close

51315-5898-General and Localized Corrosion in a Tail Gas Treating Quencher Column

Product Number: 51315-5898-SG
ISBN: 5898 2015 CP
Author: Riky Bernardo
Publication Date: 2015
$0.00
$20.00
$20.00
The quencher column is a part of Tail Gas Treating (TGT) Section in Sulphur Recovery Unit (SRU). The column is used to cool the gas containing H2S CO2 and SO2 by using direct counter-current contact with circulation water. Soda caustic (NaOH) is injected to the quench water to neutralize the acid in the solution.The quench water pH is one of the main parameters of maintaining the integrity of the whole quench water system. Failure to maintain the quench water pH within safe limits will cause negative effects to the system. pH neutralization is a complex issue since the required amount of neutralizer injected to the system will be very much dependent on the amount of acid and slippage CO2 to the system. Further operationally it is not easy to comply with “tight” pH specification.This paper describes the failure of TGT quencher system due to low quench water pH includes failure investigation process and operating parameters analysis and conclusion. The paper will also describe all the recommended action to improve the process to control corrosion.
The quencher column is a part of Tail Gas Treating (TGT) Section in Sulphur Recovery Unit (SRU). The column is used to cool the gas containing H2S CO2 and SO2 by using direct counter-current contact with circulation water. Soda caustic (NaOH) is injected to the quench water to neutralize the acid in the solution.The quench water pH is one of the main parameters of maintaining the integrity of the whole quench water system. Failure to maintain the quench water pH within safe limits will cause negative effects to the system. pH neutralization is a complex issue since the required amount of neutralizer injected to the system will be very much dependent on the amount of acid and slippage CO2 to the system. Further operationally it is not easy to comply with “tight” pH specification.This paper describes the failure of TGT quencher system due to low quench water pH includes failure investigation process and operating parameters analysis and conclusion. The paper will also describe all the recommended action to improve the process to control corrosion.
Also Purchased
Picture for Corrosion Risks in Tail Gas Lines Going To Sulfur Recovery Unit Incinerators
Available for download

51316-7586-Corrosion Risks in Tail Gas Lines Going To Sulfur Recovery Unit Incinerators

Product Number: 51316-7586-SG
ISBN: 7586 2016 CP
Author: Cathleen Shargay
Publication Date: 2016
$20.00
Picture for 08419 Corrosion in Gas Treating Equipment: Case Histories
Available for download

08419 Corrosion in Gas Treating Equipment: Case Histories

Product Number: 51300-08419-SG
ISBN: 08419 2008 CP
Author: Mark Andrew Moore, Majed M. Al-Qarni, and Graham R. Lobley
Publication Date: 2008
$20.00