51313-02217-Failure of UNS N07750 Springs in Oxygen Scavenger Service

Product Number: 51313-02217-SG
ISBN: 02217 2013 CP
Author: Abdul Razzaq Al-Shamari
Publication Date: 2013
$0.00
$20.00
$20.00

The springs made from Inconel X-750 and used in Oxygen Scavenger service have failed by extensive corrosion within a short span of two years. The metallurgical compatibility between the material of spring and the process fluid is excellent.

After through investigations including deposits analysis of deposits found inside the valve it was found that vapors of the oxygen scavenger have been carried into the spring chamber and condensed into liquid and then degraded due to constant influx of air through a breather valve connected to the tank.

A detailed study of design of the chemical day tank was carried out it was found that the failure has actually occurred due to a gap of communication between the designer and supplier of the chemical day tank and the client.

This paper highlights the findings of the investigation carried out and the possible recommendations that can be put in place to avoid such untoward failures.

Key words: Inconel X 750 Springs Oxygen Scavenger
 

The springs made from Inconel X-750 and used in Oxygen Scavenger service have failed by extensive corrosion within a short span of two years. The metallurgical compatibility between the material of spring and the process fluid is excellent.

After through investigations including deposits analysis of deposits found inside the valve it was found that vapors of the oxygen scavenger have been carried into the spring chamber and condensed into liquid and then degraded due to constant influx of air through a breather valve connected to the tank.

A detailed study of design of the chemical day tank was carried out it was found that the failure has actually occurred due to a gap of communication between the designer and supplier of the chemical day tank and the client.

This paper highlights the findings of the investigation carried out and the possible recommendations that can be put in place to avoid such untoward failures.

Key words: Inconel X 750 Springs Oxygen Scavenger
 

Product tags
Also Purchased
Picture for Design Flaw Induced Corrosion
Available for download

51313-02220-Design Flaw Induced Corrosion

Product Number: 51313-02220-SG
ISBN: 02220 2013 CP
Author: Abdul Razzaq Al-Shamari
Publication Date: 2013
$20.00
Picture for UNS N06056—An Improved Option for Welding in Nuclear Power Systems
Available for download

51313-02209-UNS N06056—An Improved Option for Welding in Nuclear Power Systems

Product Number: 51313-02209-SG
ISBN: 02209 2013 CP
Author: Larry Paul
Publication Date: 2013
$20.00
Picture for Chemical Inhibitor Field Trial in Effluent Water Treatment Facilities
Available for download

51313-02221-Chemical Inhibitor Field Trial in Effluent Water Treatment Facilities

Product Number: 51313-02221-SG
ISBN: 02221 2013 CP
Author: Amer Jarragh
Publication Date: 2013
$20.00