51313-02465-Factors Affecting Corrosion in Low Conductivity Geothermal Water

Product Number: 51313-02465-SG
ISBN: 02465 2013 CP
Author: Sonja Richter
Publication Date: 2013
$0.00
$20.00
$20.00

Low-temperature geothermal water in Iceland generally has high pH low conductivity and is oxygen free resulting in negligible corrosion. However with ingress of oxygen due to contamination of fresh water as an example the corrosion rate can increase significantly. In order to establish methods of monitoring corrosion under these conditions several corrosion monitoring methods were tested in two locations in Reykjavik Iceland and one location in Keflavik Iceland. It was found that electrochemical tests tended to overestimate the corrosion rate due to the slow polarization behavior of the system while weight loss techniques required too long of an exposure to provide real-time information; although they gave reliable historical data on the corrosion that had accumulated over the previous three six or twelve month time. A differential ER-probe proved to be the most promising measurement technique for these conditions. The analysis of the corrosion products using EDS and XRD further disproved the common notion that the low corrosion rate found in the geothermal water was due to the formation of a protective iron sulfide film. No iron sulfide film was detected but with the ingress of oxygen a thick magnetite film was detected. The low corrosion rate is therefore due to the favorable water chemistry which leaves the carbon steel pipe surface vulnerable for corrosion if it is exposed to an oxidant.

Low-temperature geothermal water in Iceland generally has high pH low conductivity and is oxygen free resulting in negligible corrosion. However with ingress of oxygen due to contamination of fresh water as an example the corrosion rate can increase significantly. In order to establish methods of monitoring corrosion under these conditions several corrosion monitoring methods were tested in two locations in Reykjavik Iceland and one location in Keflavik Iceland. It was found that electrochemical tests tended to overestimate the corrosion rate due to the slow polarization behavior of the system while weight loss techniques required too long of an exposure to provide real-time information; although they gave reliable historical data on the corrosion that had accumulated over the previous three six or twelve month time. A differential ER-probe proved to be the most promising measurement technique for these conditions. The analysis of the corrosion products using EDS and XRD further disproved the common notion that the low corrosion rate found in the geothermal water was due to the formation of a protective iron sulfide film. No iron sulfide film was detected but with the ingress of oxygen a thick magnetite film was detected. The low corrosion rate is therefore due to the favorable water chemistry which leaves the carbon steel pipe surface vulnerable for corrosion if it is exposed to an oxidant.

Product tags
Also Purchased
Picture for Electrochem. Noise Analysis for Different Green Corr. Inhibitors for Mild Steel Exposed to 0.5 H2SO4
Available for download

51313-02458-Electrochem. Noise Analysis for Different Green Corr. Inhibitors for Mild Steel Exposed to 0.5 H2SO4

Product Number: 51313-02458-SG
ISBN: 02458 2013 CP
Author: adham ahmed
Publication Date: 2013
$20.00
Picture for A Thermodynamic Study of Hydrogen Sulfide Corrosion of Mild Steel
Available for download

51313-02462-A Thermodynamic Study of Hydrogen Sulfide Corrosion of Mild Steel

Product Number: 51313-02462-SG
ISBN: 02462 2013 CP
Author: Jing Ning
Publication Date: 2013
$20.00
Picture for Waterborne Acrylic Based Systems for Rust Preventive Coatings
Available for download

51313-02464-Waterborne Acrylic Based Systems for Rust Preventive Coatings

Product Number: 51313-02464-SG
ISBN: 02464 2013 CP
Author: Ben Faber
Publication Date: 2013
$20.00