Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51313-02290-Design of Multiphase Offshore Gas Pipelines with High Risk of Sweet Top of the Line Corrosion

Product Number: 51313-02290-SG
ISBN: 02290 2013 CP
Author: Yves Gunaltun
Publication Date: 2013
$0.00
$20.00
$20.00

When the first TLC case was detected in multyphase gas pipelines several mechanisms different corrosion control and monitoring systems were porposed. Development of some prediction models concerning water condensaiton retes for different types of heat insulations and also corrosion rate  were initiated. Some of the corrosion control systems have been quite successful and new ones like volatile corrosion inhibitors are currently under developpement. Even though significan amount of knowledge have beed produced for the design of pipelines many of the data used for this purpose have field origin and subject to verification and confirmation. The paper describes most important developments during last 15 years and discuss degree of confidence in the proposed mechanisms the reliability the available data degree oof confidence in corrosion control and monitoring systems and degree of validity of the models used for design.

When the first TLC case was detected in multyphase gas pipelines several mechanisms different corrosion control and monitoring systems were porposed. Development of some prediction models concerning water condensaiton retes for different types of heat insulations and also corrosion rate  were initiated. Some of the corrosion control systems have been quite successful and new ones like volatile corrosion inhibitors are currently under developpement. Even though significan amount of knowledge have beed produced for the design of pipelines many of the data used for this purpose have field origin and subject to verification and confirmation. The paper describes most important developments during last 15 years and discuss degree of confidence in the proposed mechanisms the reliability the available data degree oof confidence in corrosion control and monitoring systems and degree of validity of the models used for design.

Product tags
Also Purchased
Picture for 08471 The Use of Inspection Results for the Evaluation of Batch Treatment Efficiency and the Remaini
Available for download

08471 The Use of Inspection Results for the Evaluation of Batch Treatment Efficiency and the Remaining Life of the Pipelines Subjected to Top of Line Corrosion

Product Number: 51300-08471-SG
ISBN: 08471 2008 CP
Author: Matina Thammachart, Yves Gunaltun, and Suchada Punpruk
Publication Date: 2008
$20.00
Picture for 00071 CORRELATION OF CASES OF TOP OF LINE
Available for download

00071 CORRELATION OF CASES OF TOP OF LINE CORROSION WITH CALCULATED WATER CONDENSATION RATES

Product Number: 51300-00071-SG
ISBN: 00071 2000 CP
Author: Y.M. Gunaltun, D. Larrey
$20.00
Picture for 01033 CONTROL OF TOP OF LINE CORROSION
Available for download

01033 CONTROL OF TOP OF LINE CORROSION BY CHEMICAL TREATMENT

Product Number: 51300-01033-SG
ISBN: 01033 2001 CP
Author: Yves M. Gunaltun, Ahmed Belghazi
$20.00