Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51315-5907-Design Installation and Commissioning of CP Systems for an Existing Seawater Concrete Structure

Product Number: 51315-5907-SG
ISBN: 5907 2015 CP
Author: Jeevanandam Shanmugam
Publication Date: 2015
$0.00
$0.00
$0.00
The cooling water for the RasGas LNG processing facility returns to the sea through pipes to a seawater outfall weir box reinforced concrete structure where it passes over a weir to a channel and back to the sea.The water enters the outfall/discharge structure at high velocity and the resulting turbulence over the weir creates a large amount of seawater splash and spray over the internal as well as external portion of the side walls. The very humid environment created by the seawater spray is very corrosive. Chloride levels at the depth of reinforcement had exceeded threshold levels and reinforcement corrosion had started to cause cracks and delamination of the concretecover.Reinforcement corrosion study was conducted on the external surface of the walls in accordance with NACE SP 0308. Following the condition assessment it was decided to install an impressed current cathodic protection system to extend the life of the structure.This paper describes the condition assessment and the tests required as per NACE SP0308 especially on the chloride content cathodic protection design and installation of cathodic protection system during regular operations and particularly how the harsh conditions of the discharge structure were overcome to install test and commission an effective corrosion control system.
The cooling water for the RasGas LNG processing facility returns to the sea through pipes to a seawater outfall weir box reinforced concrete structure where it passes over a weir to a channel and back to the sea.The water enters the outfall/discharge structure at high velocity and the resulting turbulence over the weir creates a large amount of seawater splash and spray over the internal as well as external portion of the side walls. The very humid environment created by the seawater spray is very corrosive. Chloride levels at the depth of reinforcement had exceeded threshold levels and reinforcement corrosion had started to cause cracks and delamination of the concretecover.Reinforcement corrosion study was conducted on the external surface of the walls in accordance with NACE SP 0308. Following the condition assessment it was decided to install an impressed current cathodic protection system to extend the life of the structure.This paper describes the condition assessment and the tests required as per NACE SP0308 especially on the chloride content cathodic protection design and installation of cathodic protection system during regular operations and particularly how the harsh conditions of the discharge structure were overcome to install test and commission an effective corrosion control system.
Product tags
Also Purchased
Picture for Condition Assessment ICCP Design Installation and Commissioning for a Carbonated and Salt Contami
Available for download

51315-5696-Condition Assessment ICCP Design Installation and Commissioning for a Carbonated and Salt Contaminated Reinforced Concrete Parking Deck

Product Number: 51315-5696-SG
ISBN: 5696 2015 CP
Author: Sujay Math
Publication Date: 2015
$0.00
Picture for A Novel Pulsed Eddy Current Technology for the Inline Inspection of Cement Lined Piping
Available for download

51315-5951-A Novel Pulsed Eddy Current Technology for the Inline Inspection of Cement Lined Piping

Product Number: 51315-5951-SG
ISBN: 5951 2015 CP
Author: Kamalu Koenig
Publication Date: 2015
$0.00
Picture for Advanced Analytical Techniques for Characterization of Rusted Steels
Available for download

51315-5986-Advanced Analytical Techniques for Characterization of Rusted Steels

Product Number: 51315-5986-SG
ISBN: 5986 2015 CP
Author: Seifollah Nasrazadani
Publication Date: 2015
$0.00