51312-01169-Corrosion Resistant Steel Pipe Replacement for Fire Suppression System at a Fuel Tank Farm

Product Number: 51312-01169-SG
ISBN: 01169 2012 CP
Author: Larry D. Stephenson
Publication Date: 2012
$0.00
$20.00
$20.00
Sections of mild steel above-ground water-foam conveyance pipes were found to be leaking due to severe corrosion. These pipes were part of a deluge (fire suppression system) for a large fuel tank farm operated by the U. S. Army in Okinawa Japan. Analysis of cross sections of the pipes indicated that corrosion had initiated on the exterior of the pipes most likely due to salt–laden rain water running down the sides and collecting on the underside. The corrosion was especially severe at the saddles where the pipes were supported and the chloride-containing water could easily pond. The most severely corroded pipe sections of the pipes were replaced with 304L stainless steel and the fasteners were replaced with 316L stainless steel which are expected to be more resistant to the severely corrosive atmospheric environment. Although the total installed cost of the new stainless steel replacement is 25% greater than the cost of the replacing with similar mild steel preliminary cost/benefits analysis indicates an expected useful life that exceeds 100 years for the stainless steel pipe and fasteners as compared with the observed 17 year life of low-carbon steel pipe. Details of the analysis materials selection and replacement will be discussed.
Sections of mild steel above-ground water-foam conveyance pipes were found to be leaking due to severe corrosion. These pipes were part of a deluge (fire suppression system) for a large fuel tank farm operated by the U. S. Army in Okinawa Japan. Analysis of cross sections of the pipes indicated that corrosion had initiated on the exterior of the pipes most likely due to salt–laden rain water running down the sides and collecting on the underside. The corrosion was especially severe at the saddles where the pipes were supported and the chloride-containing water could easily pond. The most severely corroded pipe sections of the pipes were replaced with 304L stainless steel and the fasteners were replaced with 316L stainless steel which are expected to be more resistant to the severely corrosive atmospheric environment. Although the total installed cost of the new stainless steel replacement is 25% greater than the cost of the replacing with similar mild steel preliminary cost/benefits analysis indicates an expected useful life that exceeds 100 years for the stainless steel pipe and fasteners as compared with the observed 17 year life of low-carbon steel pipe. Details of the analysis materials selection and replacement will be discussed.
Product tags
Also Purchased
Picture for 00653 REMEDIATION OF CORROSION PROBLEMS
Available for download

00653 REMEDIATION OF CORROSION PROBLEMS INSIDE FIRE SPRINKLER SYSTEM PIPING

Product Number: 51300-00653-SG
ISBN: 00653 2000 CP
Author: S. Steven Carl
$20.00
Picture for 10217 Corrosion of Fire Protection System Lines at the Nevada Test Site's Device Assembly Facility
Available for download

10217 Corrosion of Fire Protection System Lines at the Nevada Test Site's Device Assembly Facility

Product Number: 51300-10217-SG
ISBN: 10217 2010 CP
Author: Glenn Edgemon, Dr. Graham Bell and Gary G. Baker
Publication Date: 2010
$20.00
Picture for 00401 MICROBIOLOGICALLY INFLUENCED CORROSION
Available for download

00401 MICROBIOLOGICALLY INFLUENCED CORROSION IN FIRE PROTECTION SPRINKLER SYSTEMS

Product Number: 51300-00401-SG
ISBN: 00401 2000 CP
Author: Daniel H. Pope and Rebecca M. Pope
$20.00