A Corrosion Control Plan was developed for a Debutanizer Overhead System, which had suffered from high corrosion rates and multiple leaks. This paper will outline the efforts undertaken and conclude with the Corrosion Control Plan, developed to enhance reliability and availability of the unit and mitigate corrosion damage.

Product Number: 51316-7273-SG
ISBN: 7273 2016 CP
Author: OMAR ALABDULGADER
Publication Date: 2016
$0.00
$20.00
$20.00

A Corrosion Control Plan was developed for a Debutanizer Overhead System, which had suffered from high corrosion rates and multiple leaks resulting in interruption of unit operations. Several efforts by multidisciplinary teams had been undertaken over many years to mitigate the corrosion damage. These efforts were reactive and did not address the root causes of the damage, namely "design deficiencies" and "not implementing process monitoring." This paper will outline the significant efforts undertaken throughout the years and conclude with the Corrosion Control Plan, developed to enhance reliability and availability of the unit and proactively mitigate corrosion damage.

Key words: downloadable, Corrosion Control Plan, Hydrocracking Unit, Debutanizer Overhead System, Ammonium Bisulfide Corrosion, Corrosion Loops, Damage Mechanisms, Risk Based Inspection, Integrity Operating Windows

BACKGROUND

 

A Corrosion Control Plan was developed for a Debutanizer Overhead System, which had suffered from high corrosion rates and multiple leaks resulting in interruption of unit operations. Several efforts by multidisciplinary teams had been undertaken over many years to mitigate the corrosion damage. These efforts were reactive and did not address the root causes of the damage, namely "design deficiencies" and "not implementing process monitoring." This paper will outline the significant efforts undertaken throughout the years and conclude with the Corrosion Control Plan, developed to enhance reliability and availability of the unit and proactively mitigate corrosion damage.