51318-11045-Corrosion Behavior of Buried Pipeline under Dynamic DC Stay Current Interference

For a buried pipeline under dynamic DC stray current interference, field experiments of corrosion coupons were carried out at two selected test stations by burying coupons of different bare areas at two different depths.

Product Number: 51318-11045-SG
Author: Huimin Qin / Yanxia Du / Jie Liu / Zhengxiong Liu / Xin He
Publication Date: 2018
$0.00
$20.00
$20.00

For a buried pipeline under dynamic DC stray current interference, field experiments of corrosion coupons were carried out at two selected test stations by burying coupons of different bare areas at two different depths. Twenty-four hour on/off potential and coupon current density monitoring were also carried out for each coupon which leaded to a new method for the evaluation of dynamic stray current interference and related corrosion possibility. Corrosion rate of the stray current affected pipeline was estimated via coupon current monitoring and was compared to weight loss measurements.

 

Key words: dynamic DC stray current, buried pipeline, corrosion rate, current density

For a buried pipeline under dynamic DC stray current interference, field experiments of corrosion coupons were carried out at two selected test stations by burying coupons of different bare areas at two different depths. Twenty-four hour on/off potential and coupon current density monitoring were also carried out for each coupon which leaded to a new method for the evaluation of dynamic stray current interference and related corrosion possibility. Corrosion rate of the stray current affected pipeline was estimated via coupon current monitoring and was compared to weight loss measurements.

 

Key words: dynamic DC stray current, buried pipeline, corrosion rate, current density