51314-3946-Correlation between Streicher and EPR Test

Product Number: 51314-3946-SG
ISBN: 3946 2014 CP
Author: Roland Lackner
Publication Date: 2014
$0.00
$0.00
$0.00
For characterisation of susceptibility to intergranular corrosion different test methods are used. These tests are immersion test such as Streicher- Strauss- or Huey- test as well as electrochemical methods like the EPR test (electrochemical potentiokinetik reactivation) and the oxalic acid test. Where long term immersion test mainly evaluate grain dropping short term electrochemical tests are evaluating grain etching. In this work are each of one group of testing methods has been evaluated. These are the ASTM G28A Streicher test and the ASTM G108 EPR test. The results of both tests are compared for various CRAs (corrosion resist alloys). Alloys investigated are 316L 926 and 625. There is always a good correlation between both tests except when discontinuous depletion zone are present in the material. The advantage of short testing time of EPR is partially compensated by the necessary of optimization for each single material.
For characterisation of susceptibility to intergranular corrosion different test methods are used. These tests are immersion test such as Streicher- Strauss- or Huey- test as well as electrochemical methods like the EPR test (electrochemical potentiokinetik reactivation) and the oxalic acid test. Where long term immersion test mainly evaluate grain dropping short term electrochemical tests are evaluating grain etching. In this work are each of one group of testing methods has been evaluated. These are the ASTM G28A Streicher test and the ASTM G108 EPR test. The results of both tests are compared for various CRAs (corrosion resist alloys). Alloys investigated are 316L 926 and 625. There is always a good correlation between both tests except when discontinuous depletion zone are present in the material. The advantage of short testing time of EPR is partially compensated by the necessary of optimization for each single material.
Product tags
Also Purchased
Picture for Corrosion in a Hydrocracking Unit
Available for download

51314-3936-Corrosion in a Hydrocracking Unit

Product Number: 51314-3936-SG
ISBN: 3936 2014 CP
Author: Vinod Ramaseshan
Publication Date: 2014
$0.00
Picture for Effect of H2S Content and Corrosion Products on Hydrogen Permeation of Pipeline Steel
Available for download

51314-3938-Effect of H2S Content and Corrosion Products on Hydrogen Permeation of Pipeline Steel

Product Number: 51314-3938-SG
ISBN: 3938 2014 CP
Author: DaPeng Li
Publication Date: 2014
$0.00
Picture for Practical Aspects of MIC Detection Monitoring and Management in the Oil & Gas Industry
Available for download

51314-3920-Practical Aspects of MIC Detection Monitoring and Management in the Oil & Gas Industry

Product Number: 51314-3920-SG
ISBN: 3920 2014 CP
Author: Torben Lund Skovhus
Publication Date: 2014
$0.00