Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51314-3837-Choking of Oxygen Scavenger Injection Quills

Product Number: 51314-3837-SG
ISBN: 3837 2014 CP
Author: Abdul Razzaq Al-Shamari
Publication Date: 2014
$0.00
$0.00
$0.00
“Kuwait Oil Company (KOC) is a major Oil producing company in the state of Kuwait. Chemical treatment is a primary measures for mitigating internal corrosion of process equipment at crude gathering centers as part of asset integrity management. As oxygen is highly oxidizing agent for corrosion Oxygen Scavenger is injected to the brackish water stream to minimize the dissolved oxygen in the system and hence to mitigate corrosion.The Oxygen Scavenger has a property of crystalizing at low temperatures below -100C (14oF). This crystallization can affect the injection at the quills’ end. In the present case study many oxygen scavenger injection quills found to be chocked at the tip of injection quill preventing the actual flow of chemicals to the brackish water stream. Therefore the case study shall cover the investigation to identify the main root cause for choking the quill and remedial measures to prevent the choking.Key words: Oxygen Scavenger injection quills crystallization choking. 
“Kuwait Oil Company (KOC) is a major Oil producing company in the state of Kuwait. Chemical treatment is a primary measures for mitigating internal corrosion of process equipment at crude gathering centers as part of asset integrity management. As oxygen is highly oxidizing agent for corrosion Oxygen Scavenger is injected to the brackish water stream to minimize the dissolved oxygen in the system and hence to mitigate corrosion.The Oxygen Scavenger has a property of crystalizing at low temperatures below -100C (14oF). This crystallization can affect the injection at the quills’ end. In the present case study many oxygen scavenger injection quills found to be chocked at the tip of injection quill preventing the actual flow of chemicals to the brackish water stream. Therefore the case study shall cover the investigation to identify the main root cause for choking the quill and remedial measures to prevent the choking.Key words: Oxygen Scavenger injection quills crystallization choking. 
Product tags
Also Purchased
Picture for Comprehensive Approach to Oxygen Corrosion Analysis of Water Injection Systems
Available for download

Comprehensive Approach to Oxygen Corrosion Analysis of Water Injection Systems

Product Number: 51315-5962-SG
ISBN: 5962 2015 CP
Author: Troy Eggum
Publication Date: 2015
$0.00