In the arid or semi-arid western part of the United States, there are special parameters that may require investigation to determine whether the right-of-way soils are comosive to cementitious-coated pipe. Cyclical wetting and drying, especially in arid environments, can cause an increase in chloride concentration in the capillary system of mortar by a factor of at least five. Under the right circumstances, with cyclical wetting and drying, a soil chloride content of 140 mg/kg will exceed the corrosion threshold of 700 mg/kg and initiate corrosion on prestress wire. Several actual field examples encountered in an investigation on a PCCP failure are described. Also included is a simple field test to quickly and economically determine which combinations of gravel, sand, and silty clay that are helpfid in predicting both the likelihood and severity of cyclical wetting and drying stimulated corrosion on prestress concrete cylinder pipe. Other parameters examined were mortar properties of thickness, compressive strength, absorption, density, pH and total alkalinity vs. chloride penetration into the mortar, and degree of corrosion on prestress concrete cylinder pipe. Keywords: Cyclical wetting and drying, prestress concrete cylinder pipe, mortar absorption, density, pH and total alkalinity, total acidity, redox, Apparent Corrosion Intensity Profile
In the arid or semi-arid western part of the United States, there are special parameters that may require investigation to determine whether the right-of-way soils are comosive to cementitious-coated pipe. Cyclical wetting and drying, especially in arid environments, can cause an increase in chloride concentration in the capillary system of mortar by a factor of at least five. Under the right circumstances, with cyclical wetting and drying, a soil chloride content of 140 mg/kg will exceed the corrosion threshold of 700 mg/kg and initiate corrosion on prestress wire. Several actual field examples encountered in an investigation on a PCCP failure are described. Also included is a simple field test to quickly and economically determine which combinations of gravel, sand, and silty clay that are helpfid in predicting both the likelihood and severity of cyclical wetting and drying stimulated corrosion on prestress concrete cylinder pipe. Other parameters examined were mortar properties of thickness, compressive strength, absorption, density, pH and total alkalinity vs. chloride penetration into the mortar, and degree of corrosion on prestress concrete cylinder pipe. Keywords: Cyclical wetting and drying, prestress concrete cylinder pipe, mortar absorption, density, pH and total alkalinity, total acidity, redox, Apparent Corrosion Intensity Profile
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 98637 CATHODIC PROTECTION CRITERIA FOR PRESTRESSED
Available for download

98637 CATHODIC PROTECTION CRITERIA FOR PRESTRESSED CONCRETE PIPE

Product Number: 51300-98637-SG
ISBN: 98637 1998 CP
Author: Sylvia C. Hall
$20.00