In-situ AC and DC electrochemical techniques were used to determine the corrosion rate and corrosion potential of high purity iron under alternate wet and dry conditions. Comparisons between DC electrochemical measurements and weight loss were also performed to verify the validity of the corrosion rate measurements. Identification of the corrosion products was performed using Raman spectroscopy. The corrosion products were found to contain layers of iron oxides and oxyhydroxides. At low chloride concentrations the corrosion products
consisted of...