98286 PREVENTION OF MICROBIOLOGICAL INFLUENCED CORROSION IN FIRE PROTECTION SYSTEMS AT A SEMICONDUCTOR MANUFACTURING FACILITY

Product Number: 51300-98286-SG
ISBN: 98286 1998 CP
Author: Gary S. McReynolds
$0.00
$20.00
$20.00
Application of an effective prevention program for microbiological influenced corrosion (MIC) can be as varied as there are types of systems that are susceptible to this corrosion process. Fire protection systems by their design, are typically stagnant reservoirs of untreated water that provide ideal environmental conditions for MIC to proliferate, resulting in expensive but necessary repairs. There is particular concern when these systems are installed over manufacturing cleanroom space, with the potential of eventual pipe failure causing major impacts to production. Since absolute effectiveness of any treatment program in fire sprinkler systems would take years to validate, there is evidence to believe that through application of certain piping arrangements in the system and a consistent treatment program, formation of MIC can be prevented or delayed and pipe repairs postponed for scheduled downtime. Keywords: microbiological influenced corrosion, ( MIC), fire protection, sprinklers, treatment, preventative maintenance.
Application of an effective prevention program for microbiological influenced corrosion (MIC) can be as varied as there are types of systems that are susceptible to this corrosion process. Fire protection systems by their design, are typically stagnant reservoirs of untreated water that provide ideal environmental conditions for MIC to proliferate, resulting in expensive but necessary repairs. There is particular concern when these systems are installed over manufacturing cleanroom space, with the potential of eventual pipe failure causing major impacts to production. Since absolute effectiveness of any treatment program in fire sprinkler systems would take years to validate, there is evidence to believe that through application of certain piping arrangements in the system and a consistent treatment program, formation of MIC can be prevented or delayed and pipe repairs postponed for scheduled downtime. Keywords: microbiological influenced corrosion, ( MIC), fire protection, sprinklers, treatment, preventative maintenance.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 00401 MICROBIOLOGICALLY INFLUENCED CORROSION
Available for download

00401 MICROBIOLOGICALLY INFLUENCED CORROSION IN FIRE PROTECTION SPRINKLER SYSTEMS

Product Number: 51300-00401-SG
ISBN: 00401 2000 CP
Author: Daniel H. Pope and Rebecca M. Pope
$20.00
Picture for 00653 REMEDIATION OF CORROSION PROBLEMS
Available for download

00653 REMEDIATION OF CORROSION PROBLEMS INSIDE FIRE SPRINKLER SYSTEM PIPING

Product Number: 51300-00653-SG
ISBN: 00653 2000 CP
Author: S. Steven Carl
$20.00
Picture for 04602 A Microbiologically Influenced Corrosion
Available for download

04602 A Microbiologically Influenced Corrosion Study in Fire Protection Systems

Product Number: 51300-04602-SG
ISBN: 04602 2004 CP
Author: Geary G. Yee and Michael R. Whitbeck, FM Global Research
$20.00