Search
Filters
Close

11337 Demonstration of a New Generation of Stainless Steel Corrosion-Resistant Fire Hydrant Retrofit, “No-Dig” System Which Also Protects Against Deliberate/Accidental Contamination of Critical Water Supplies

Product Number: 51300-11337-SG
ISBN: 11337 2011 CP
Author: Eddy D. Smith, Mark Ginsberg, Vicki VanBlaricum and Vince Hock
Publication Date: 2011
$0.00
$20.00
$20.00
There is a need in both the military and public sectors to upgrade existing, older-generation fire hydrants with a new-generation system which is corrosion-resistant and also helps to prevent deliberate injection of chemical/biological contaminants into the drinking water systems. Unfortunately, it is very common for many hydrants to be internally severely corroded enough that they will not operate at a critical time—during a fire. This inoperability is caused by corrosion of the older cold-rolled steel stems to such an extent that the fire fighter is unable to open the hydrant’s water valve. As part of the Army and Department of Defense (DOD) Corrosion Program, 90 older-generation corroded (and difficult to open) fire hydrants of various brand names, models, and vintages have been upgraded with a newgeneration retrofit system at a major Army installation. The innovative, but off-the-shelf product requires no expensive excavation and promises to be reliable, economical, and corrosion-resistant since the main component is manufactured of series 304 stainless steel. A demonstration and evaluation project is underway and will conclude in March 2012.

Key words: fire hydrant, corrosion-resistant, water security
There is a need in both the military and public sectors to upgrade existing, older-generation fire hydrants with a new-generation system which is corrosion-resistant and also helps to prevent deliberate injection of chemical/biological contaminants into the drinking water systems. Unfortunately, it is very common for many hydrants to be internally severely corroded enough that they will not operate at a critical time—during a fire. This inoperability is caused by corrosion of the older cold-rolled steel stems to such an extent that the fire fighter is unable to open the hydrant’s water valve. As part of the Army and Department of Defense (DOD) Corrosion Program, 90 older-generation corroded (and difficult to open) fire hydrants of various brand names, models, and vintages have been upgraded with a newgeneration retrofit system at a major Army installation. The innovative, but off-the-shelf product requires no expensive excavation and promises to be reliable, economical, and corrosion-resistant since the main component is manufactured of series 304 stainless steel. A demonstration and evaluation project is underway and will conclude in March 2012.

Key words: fire hydrant, corrosion-resistant, water security
Product tags
Also Purchased
Picture for 11327 Effects of Temperature on CO2 Top of Line Corrosion of Pipeline Steel
Available for download

11327 Effects of Temperature on CO2 Top of Line Corrosion of Pipeline Steel

Product Number: 51300-11327-SG
ISBN: 2011 11327 CP
Author: Yingfeng Chen, Lei Zhang, Huimin Qin, Lining Xu, Minxu Lu
Publication Date: 2011
$20.00
Picture for 11335 Soil Moisture Control Using Intelligent Single-Well Electro-Osmotic Dewatering Systems
Available for download

11335 Soil Moisture Control Using Intelligent Single-Well Electro-Osmotic Dewatering Systems

Product Number: 51300-11335-SG
ISBN: 11335 2011 CP
Author: Orange S. Marshall, Sean W. Morefield, Philip G. Malone and Charles A. Weiss
Publication Date: 2011
$20.00
Picture for 11329 Role of Acetic Acid in CO2 Top of The Line Corrosion of Carbon Steel
Available for download

11329 Role of Acetic Acid in CO2 Top of The Line Corrosion Carbon Steel

Product Number: 51300-11329-SG
ISBN: 2011 11329 CP
Author: Jamel Anri, Egil Gulbrandsen and Ricardo P. Nogueira
Publication Date: 2011
$20.00