Search
Filters
Close

11262 Under-deposit Corrosion Failure of a Compressor after Stage Cooler at an NGL Plant- A Case Study

Product Number: 51300-11262-SG
ISBN: 2011 11262 CP
Author: S. A. Al-Dossary, A. K. Debbert and M. A. Al- Mubayidh
Publication Date: 2011
$0.00
$20.00
$20.00
Premature tube leaks were encountered at a compressor after-stage cooler operating at 100-130?F (37.8-54.4?C) after three years in service due to under-deposit corrosion. The damage encountered was confirmed by visual, metallurgical examination and chemical analysis of corrosion products. The premature failure resulted from condensation of water containing dissolved carbon dioxide, hydrogen sulfide and possibly oxygen at the center bottom portion of the tube. Moreover, the presence of pitting in the liquid phase area indicates that the injection of the oil soluble water dispersible corrosion inhibitor was not effective. Chemical analysis of the deposits revealed that they comprised mainly of iron sulfide products. Metallurgical examination revealed no manufacturing defects. Corrective actions of similar failures are discussed in terms of design and inhibition.

Keywords: fin fan, corrosion inhibitor, hydrogen sulfide, failure analysis, Pourbaix diagram, mitigation
Premature tube leaks were encountered at a compressor after-stage cooler operating at 100-130?F (37.8-54.4?C) after three years in service due to under-deposit corrosion. The damage encountered was confirmed by visual, metallurgical examination and chemical analysis of corrosion products. The premature failure resulted from condensation of water containing dissolved carbon dioxide, hydrogen sulfide and possibly oxygen at the center bottom portion of the tube. Moreover, the presence of pitting in the liquid phase area indicates that the injection of the oil soluble water dispersible corrosion inhibitor was not effective. Chemical analysis of the deposits revealed that they comprised mainly of iron sulfide products. Metallurgical examination revealed no manufacturing defects. Corrective actions of similar failures are discussed in terms of design and inhibition.

Keywords: fin fan, corrosion inhibitor, hydrogen sulfide, failure analysis, Pourbaix diagram, mitigation
Product tags
Also Purchased
Picture for 11266 Under Deposit Corrosion From Iron Sulfide
Available for download

11266 Under Deposit Corrosion From Iron Sulfide

Product Number: 51300-11266-SG
ISBN: 2011 11266 CP
Author: Sarah Standlee, K. Daniel Efird, Derek Spiller
Publication Date: 2011
$20.00
Picture for 11260 Prediction of Uniform CO2 Corrosion of Mild Steel under Inert Solid Deposits
Available for download

11260 Prediction of Uniform CO2 Corrosion of Mild Steel under Inert Solid Deposits

Product Number: 51300-11260-SG
ISBN: 2011 11260 CP
Author: Jin Huang, Bruce Brown, Yoon-Seok Choi and Srdjan Nešic
Publication Date: 2011
$20.00