Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

10401 Prevention of Corrosion in Carbon Steel Pipelines Containing Hydrotest Water-An Overview

Product Number: 51300-10401-SG
ISBN: 10401 2010 CP
Author: Adam Darwin, Karthik Annadorai and Krista Heidersbach
Publication Date: 2010
$0.00
$20.00
$20.00
A critical step in proving a pipeline is fit for operational use is the hydrostatic test, in which it is filled with water and pressurized to 125% of its Maximum Allowable Operating Pressure (MAOP). The water that is used in this testing can cause corrosion of the pipe, potentially leading to failure early in its operating life. Failures have occasionally been reported even before a pipeline enters service.

The most common mechanisms by which carbon steel pipelines may undergo corrosion on exposure to hydrotest water are Microbially Induced Corrosion (MIC), oxygen-related corrosion, galvanic corrosion and under-deposit corrosion. An overview of these mechanisms is presented, along with a discussion of the influence of different environmental factors on them. Factors considered include water source, degree of filtration, exposure period and temperature, air pockets, presence of internal pipe coatings and future pipeline service conditions.

Maintaining the risk of pipe corrosion from hydrotest water within acceptable limits is discussed. Factors considered are:

• How long the untreated water may be allowed to be present in the pipeline.

• Should water treatment be required, what must be used?

• Disposal requirements for the treated water, including chemical treatments.

Key Words: Hydrostatic, Hydrotest, MIC, Microbially Induced Corrosion, Pipeline, Oxygen-Related Corrosion, Under Deposit Corrosion, Internal Coating, Biocide, Corrosion Inhibitor, Oxygen Scavenger
A critical step in proving a pipeline is fit for operational use is the hydrostatic test, in which it is filled with water and pressurized to 125% of its Maximum Allowable Operating Pressure (MAOP). The water that is used in this testing can cause corrosion of the pipe, potentially leading to failure early in its operating life. Failures have occasionally been reported even before a pipeline enters service.

The most common mechanisms by which carbon steel pipelines may undergo corrosion on exposure to hydrotest water are Microbially Induced Corrosion (MIC), oxygen-related corrosion, galvanic corrosion and under-deposit corrosion. An overview of these mechanisms is presented, along with a discussion of the influence of different environmental factors on them. Factors considered include water source, degree of filtration, exposure period and temperature, air pockets, presence of internal pipe coatings and future pipeline service conditions.

Maintaining the risk of pipe corrosion from hydrotest water within acceptable limits is discussed. Factors considered are:

• How long the untreated water may be allowed to be present in the pipeline.

• Should water treatment be required, what must be used?

• Disposal requirements for the treated water, including chemical treatments.

Key Words: Hydrostatic, Hydrotest, MIC, Microbially Induced Corrosion, Pipeline, Oxygen-Related Corrosion, Under Deposit Corrosion, Internal Coating, Biocide, Corrosion Inhibitor, Oxygen Scavenger
Product tags
Also Purchased
Picture for 10404 Protection Against Microbiologically Influenced Corrosion by Effective Treatment
Available for download

10404 Protection Against Microbiologically Influenced Corrosion by Effective Treatment and Monitoring During Hydrotest Shut-In

Product Number: 51300-10404-SG
ISBN: 10404 2010 CP
Author: Joseph E. Penkala, Jennifer Fichter, and
Publication Date: 2010
$20.00
Picture for 03572 CHEMICAL TREATMENT OPTIONS FOR HYDROTEST
Available for download

03572 CHEMICAL TREATMENT OPTIONS FOR HYDROTEST

Product Number: 51300-03572-SG
ISBN: 03572 2003 CP
Publication Date: 2003
$20.00