Search
Filters
Close

10199 Cost Effective Weld Overlay Alloys for Waste-to-Energy Systems

Product Number: 51300-10199-SG
ISBN: 10199 2010 CP
Author: Larry D. Paul and Gregg Clark
Publication Date: 2010
$0.00
$20.00
$20.00
Alloy 625 (UNS N06625) has successfully been used as a weld overlay for many years in waste-toenergy systems to combat corrosion. UNS N06625 will likely remain the preferred alloy for the most aggressive regions of the boiler; however there are other regions in the system where leaner and less costly weld overlay materials are more than sufficient. Alloy 31 (UNS N08031), with 31%Ni-28%Cr- 6.5%Mo, has been tested in both the laboratory and in the field with corrosion resistance approaching that of UNS N06625 in many cases and is significantly less expensive than UNS N06625. A comparison of the corrosion resistance of UNS N08031against other alloys is presented. In addition, field data is presented from various field tests and is shown to support laboratory corrosion based empirical model previously suggested by other researchers. This model is used to project the corrosion response of UNS N08031 in the field, which is further supported by 2 year field exposures in one boiler. Lastly an economic analysis is used help select the best material for various locations in the waste-to-energy boiler.

Keywords: Refuse-Fired Boiler, Weld Overlay, Nickel Alloy, Field Tests, Modeling
Alloy 625 (UNS N06625) has successfully been used as a weld overlay for many years in waste-toenergy systems to combat corrosion. UNS N06625 will likely remain the preferred alloy for the most aggressive regions of the boiler; however there are other regions in the system where leaner and less costly weld overlay materials are more than sufficient. Alloy 31 (UNS N08031), with 31%Ni-28%Cr- 6.5%Mo, has been tested in both the laboratory and in the field with corrosion resistance approaching that of UNS N06625 in many cases and is significantly less expensive than UNS N06625. A comparison of the corrosion resistance of UNS N08031against other alloys is presented. In addition, field data is presented from various field tests and is shown to support laboratory corrosion based empirical model previously suggested by other researchers. This model is used to project the corrosion response of UNS N08031 in the field, which is further supported by 2 year field exposures in one boiler. Lastly an economic analysis is used help select the best material for various locations in the waste-to-energy boiler.

Keywords: Refuse-Fired Boiler, Weld Overlay, Nickel Alloy, Field Tests, Modeling
Product tags
Also Purchased
Picture for 10219 Microbiologically Influenced Corrosion of Carbon Steel in an Aqueous Natural Gas Plant
Available for download

10219 Microbiologically Influenced Corrosion of Carbon Steel in an Aqueous Natural Gas Plant

Product Number: 51300-10219-SG
ISBN: 10219 2010 CP
Author: Yasunori Tanji, Takuya Handa, and Kazuhiko Miyanaga
Publication Date: 2010
$20.00
Picture for 10198 Oxidation Behavior of Alumina-Forming Alloys in CO2-H2O Environment
Available for download

10198 Oxidation Behavior of Alumina-Forming Alloys in CO2-H2O Environment

Product Number: 51300-10198-SG
ISBN: 10198 2010 CP
Author: Bruce A. Pint and Ian G. Wright
Publication Date: 2010
$20.00
Picture for 10218 Iron-Oxidizing Bacteria: A Review of Corrosion Mechanisms in Fresh Water & Marine Environments
Available for download

10218 Iron-Oxidizing Bacteria: A Review of Corrosion Mechanisms in Fresh Water and Marine Environments

Product Number: 51300-10218-SG
ISBN: 10218 2010 CP
Author: Richard I. Ray, Jason S. Lee, and Brenda J. Little
Publication Date: 2010
$20.00