10031 Resolving CP Design Restrictions at an Australian Wharf: A Novel Marine Impressed Current CP Systems

Product Number: 51300-10031-SG
ISBN: 10031 2010 CP
Author: Rajko Vukcevic, Ian Godson and John Furstenberg
Publication Date: 2010
$0.00
$20.00
$20.00
This paper presents resolutions to cathodic protection (CP) design restrictions at an Australian 1km long steel-pile container wharf, requiring a 3,500A impressed current CP (ICCP) system. Rectifier locations were confined to ends of the wharf, while all cablework from rectifiers to anodes and piles had to be mounted underneath the dock. In a traditionally designed ICCP system using transformer-rectifier units (TRUs) and low-voltage/high-current DC distribution, these restrictions would result in cable crosssections of up to 120mm2 per anode leg. Instead, a novel DC power distribution system was utilized, consisting of parallel channels of high-voltage/low-current Power Supply units (PSUs) feeding adjustable constant current into Current Multiplier DC/DC converters located close to anodes. Thus, power cables leading from PSUs could all be 1.0÷2.5mm2 twin-core cables, distributing 2A@300Vdc max towards each anode, where Current Multipliers transform it into 45A@9Vdc max. A single-anode prototype was developed as a proof-of-concept trial system, and then a full 77-anode ICCP system was constructed for the complete wharf corrosion protection. Major parameter values of the installed distribution cable network were considerably reduced – the average cable cross-section size by a factor of 30, the total cable weight by 12, and the total cable material and installation costs by 15÷20. Total system power consumption from AC-mains was cut down by 55%.

Keywords: current multiplier, energy efficiency, impressed current cathodic protection, marine corrosion, power distribution system
This paper presents resolutions to cathodic protection (CP) design restrictions at an Australian 1km long steel-pile container wharf, requiring a 3,500A impressed current CP (ICCP) system. Rectifier locations were confined to ends of the wharf, while all cablework from rectifiers to anodes and piles had to be mounted underneath the dock. In a traditionally designed ICCP system using transformer-rectifier units (TRUs) and low-voltage/high-current DC distribution, these restrictions would result in cable crosssections of up to 120mm2 per anode leg. Instead, a novel DC power distribution system was utilized, consisting of parallel channels of high-voltage/low-current Power Supply units (PSUs) feeding adjustable constant current into Current Multiplier DC/DC converters located close to anodes. Thus, power cables leading from PSUs could all be 1.0÷2.5mm2 twin-core cables, distributing 2A@300Vdc max towards each anode, where Current Multipliers transform it into 45A@9Vdc max. A single-anode prototype was developed as a proof-of-concept trial system, and then a full 77-anode ICCP system was constructed for the complete wharf corrosion protection. Major parameter values of the installed distribution cable network were considerably reduced – the average cable cross-section size by a factor of 30, the total cable weight by 12, and the total cable material and installation costs by 15÷20. Total system power consumption from AC-mains was cut down by 55%.

Keywords: current multiplier, energy efficiency, impressed current cathodic protection, marine corrosion, power distribution system
Product tags
Also Purchased
Picture for 07049 20 Years of Impressed Current Cathodic Protection Retrofit of Offshore Platforms Using MMO Ten
Available for download

07049 20 Years of Impressed Current Cathodic Protection Retrofit of Offshore Platforms Using MMO Tensioned Anode Strings

Product Number: 51300-07049-SG
ISBN: 07049 2007 CP
Author: Michele Tettamanti, Simone Tremolada, Manuela Manghi, Bruno Bazzoni, and Thomas Turk
Publication Date: 2007
$20.00
Picture for 09545 Interference of an Impressed CP System with an Adjacent Sacrificial CP System and its Mitigati
Available for download

09545 Interference of an Impressed CP System with an Adjacent Sacrificial CP System and its Mitigation

Product Number: 51300-09545-SG
ISBN: 09545 2009 CP
Author: Fawzi S. AL-Madani, Ezeddin R. Busba, David Scantlebury and Hussain S. Boshalla
Publication Date: 2009
$20.00