09364 Large and Small Scale SCC Testing of 316L Clad at 135 C

This work was undertaken to explore the possibility to extend the limits of 316L to higher temperatures.  The large scale test consists of a full ring pipe which is stressed externally and exposed internally to the test fluid.  The small scale tests are four-point-bend (4PB) tests in accordance with ISO15156-31 and EFC172.

Product Number: 51300-09364-SG
ISBN: 09364 2009 CP
Author: Stale Nodland, Philip Dent and Kamran Fatehi
Publication Date: 2009
$0.00
$20.00
$20.00

Use of 316L clad pipes are currently limited to 120 oC to avoid stress corrosion cracking. This work was undertaken to explore the possibility to extend the limits of 316L to higher temperatures. The testing is divided into a large scale test and a small scale test. The large scale test consists of a full ring pipe which is stressed externally and exposed internally to the test fluid. The work has also investigated the relationship between the test methods. It is the intention to find small scale tests which gives similar results as the large scale test.

The small scale tests are four-point-bend (4PB) tests in accordance with ISO15156-31 and EFC172. The test specimens are made of approximately 3mm thick clad material where the carbon steel backing has been machined off.

The tests were conducted at 135 oC with a partial pressure of 0.02 bar H2S. CO2 pressure was approx 11 and 1 bar for the small and large scale test respectively. In situ pH was adjusted to approximately 5.3. Chloride concentrations were between 40.5 and 41.8 g/l Cl-.

Keywords: clad pipes, stress corrosion cracking, test methods, four-point bend test

Use of 316L clad pipes are currently limited to 120 oC to avoid stress corrosion cracking. This work was undertaken to explore the possibility to extend the limits of 316L to higher temperatures. The testing is divided into a large scale test and a small scale test. The large scale test consists of a full ring pipe which is stressed externally and exposed internally to the test fluid. The work has also investigated the relationship between the test methods. It is the intention to find small scale tests which gives similar results as the large scale test.

The small scale tests are four-point-bend (4PB) tests in accordance with ISO15156-31 and EFC172. The test specimens are made of approximately 3mm thick clad material where the carbon steel backing has been machined off.

The tests were conducted at 135 oC with a partial pressure of 0.02 bar H2S. CO2 pressure was approx 11 and 1 bar for the small and large scale test respectively. In situ pH was adjusted to approximately 5.3. Chloride concentrations were between 40.5 and 41.8 g/l Cl-.

Keywords: clad pipes, stress corrosion cracking, test methods, four-point bend test

Also Purchased
Picture for 09367 Advanced Super-Austenitic Steel ... an Economical Alternative to Nickel-Base Corrosion-Resista
Available for download

09367 Advanced Super-Austenitic Steel ... an Economical Alternative to Nickel-Base Corrosion-Resistant Alloys

Product Number: 51300-09367-SG
ISBN: 09367 2009 CP
Author: Lewis E. Shoemaker, Ruben Muro and James R. Crum
Publication Date: 2009
$20.00
Picture for 09295 Atmospheric Chamber Testing to Evalute Chloride Induced Stress Corrosion Cracking of Type 304,
Available for download

09295 Atmospheric Chamber Testing to Evalute Chloride Induced Stress Corrosion Cracking of Type 304, 304L, and 316L Stainless Steel

Product Number: 51300-09295-SG
ISBN: 09295 2009 CP
Author: Darrell Dunn and Todd S. Mintz
Publication Date: 2009
$20.00
Picture for 02062 CLAD PLATES AND PIPES IN OIL AND...
Available for download

02062 CLAD PLATES AND PIPES IN OIL AND GAS PRODUCTION: APPLICATIONS - FABRICATION- WELDING

Product Number: 51300-02062-SG
ISBN: 02062 2002 CP
Author: J. Lettner and J. Klower, R. Behrens
$20.00