09137 Statistical Analysis of External Corrosion Anomaly Data of Cased Pipe Segments

Product Number: 51300-09137-SG
ISBN: 09137 2009 CP
Author: Barron Bichon and Fengmei Song
Publication Date: 2009
$0.00
$20.00
$20.00
Cased pipe segments can suffer external corrosion when the carrier pipe holidays are exposed to electrolyte or humid air. Corrosion by electrolyte occurs when cathodic protection (CP) is shielded by, for instance, insulator spacers, the casing wall (particularly if coated), or mud/deposits accumulated in the annulus. When the casing and carrier are metallically shorted, any CP protection to the carrier pipe may be eliminated. Understanding mechanisms and severity of external corrosion of cased carrier pipe is a significant step toward developing strategies to prevent or mitigate the corrosion problem. The severity of carrier external corrosion can be assessed through a statistical analysis of corrosion anomalies identified and sized from In-Line Inspection (ILI) runs. The results of piggable cased pipe segments can be applied to non-piggable ones given their corrosion conditions are similar. The goal of this study was to investigate the significance of external corrosion damage to cased segments, including the preferential location of the peak anomaly in a cased segment, the effect on corrosion of metallic shorts relative to non-shorted conditions, historical failure incidents in casings, and the relative safety of cased segments to non-cased ones evaluated by the number of scheduled or immediate repair anomalies per mile. These results are expected to provide insight into developing risk methodologies for identification and prioritization of cased pipe segments as part of the external corrosion direct assessment (ECDA) program of cased crossings.

Keyword: cased crossing, metallic short, ECDA, ILI, CP shielding, risk assessment
Cased pipe segments can suffer external corrosion when the carrier pipe holidays are exposed to electrolyte or humid air. Corrosion by electrolyte occurs when cathodic protection (CP) is shielded by, for instance, insulator spacers, the casing wall (particularly if coated), or mud/deposits accumulated in the annulus. When the casing and carrier are metallically shorted, any CP protection to the carrier pipe may be eliminated. Understanding mechanisms and severity of external corrosion of cased carrier pipe is a significant step toward developing strategies to prevent or mitigate the corrosion problem. The severity of carrier external corrosion can be assessed through a statistical analysis of corrosion anomalies identified and sized from In-Line Inspection (ILI) runs. The results of piggable cased pipe segments can be applied to non-piggable ones given their corrosion conditions are similar. The goal of this study was to investigate the significance of external corrosion damage to cased segments, including the preferential location of the peak anomaly in a cased segment, the effect on corrosion of metallic shorts relative to non-shorted conditions, historical failure incidents in casings, and the relative safety of cased segments to non-cased ones evaluated by the number of scheduled or immediate repair anomalies per mile. These results are expected to provide insight into developing risk methodologies for identification and prioritization of cased pipe segments as part of the external corrosion direct assessment (ECDA) program of cased crossings.

Keyword: cased crossing, metallic short, ECDA, ILI, CP shielding, risk assessment
Product tags
Also Purchased
Picture for 00726 CASED CROSSING TEST METHODS
Available for download

00726 CASED CROSSING TEST METHODS

Product Number: 51300-00726-SG
ISBN: 00726 2000 CP
Author: Dr. Thomas J. Barlo, Aida Lopez
$20.00
Picture for 11130 Monitoring Of Corrosion Parameters Within the Annular Space of Cased Natural Gas Pipelines
Available for download

11130 Monitoring Of Corrosion Parameters Within the Annular Space of Cased Natural Gas Transmission Pipelines

Product Number: 51300-11130-SG
ISBN: 2011 11130 CP
Author: Frank G. Hemerlein, Vincent Pastore and Diego Politano
Publication Date: 2011
$20.00
Picture for Case Studies in the Assessment of Filled Casings
Available for download

51313-02386-Case Studies in the Assessment of Filled Casings

Product Number: 51313-02386-SG
ISBN: 02386 2013 CP
Author: James Warner
Publication Date: 2013
$20.00